FROM WBL 191.0 TO WBL 282.0.
VORTEX
GENERATOR
VORTEX GENERATOR LINE EXAMPLE FOR LEFT WING(4 LOCATIONS)
(REF)
Wing Vortex Generator Installation Figure 401 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
57-32-00
ALL ú ú B01 Page 402 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
WING VORTEX GENERATORS - REMOVAL/INSTALLATION
_____________________________________________
1. General_______
A. This procedure contains two tasks. The first task is the removal of the wing vortex generator. The second task is the installation of the wing vortex generator.
TASK 57-32-00-004-001-B00
2. Remove the Wing Vortex Generators_________________________________
A. Standard Tools and Equipment
(1) Stick - Hardwood
B. Access
(1) Location Zones
300 Left Wing
400 Right Wing
C. Procedure - Remove the Wing Vortex Generator
S 034-002-B00
(1) Remove the loose vortex generator with a hardwood stick.
TASK 57-32-00-404-003-B00
3. Install the Wing Vortex Generator_________________________________
A. Standard Tools and Equipment
(1) Scraper - Nonmetallic
B. Consumable Materials
(1)
Solvent - BMS 11-7 or Methyl Ethyl Ketone
(2)
Paint Stripper - Del Chem EZ
(3)
Adhesive - BMS 5-79 or BMS 5-95 Class B
C. Access
(1) Location Zones
300 Left Wing
400 Right Wing
D. Procedure - Install the Wing Vortex Generator
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
57-32-00
ALL ú ú B01 Page 403 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
S 154-009-B00
WARNING: DO NOT GET METHYL ETHYL KETONE (MEK) IN YOUR MOUTH OR EYES, OR
_______ ON YOUR SKIN. DO NOT BREATHE THE FUMES FROM MEK. PUT ON A PROTECTIVE SPLASH GOGGLE AND GLOVES WHEN YOU USE MEK. KEEP MEK AWAY FROM SPARKS, FLAME AND HEAT. MEK IS A POISONOUS AND FLAMMABLE SOLVENT WHICH CAN CAUSE INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT.
(1)
Remove the remaining bonding agent with a nonmetallic scraper and solvent.
S 154-005-B00
(2)
Remove a thin layer of the paint to install the vortex generator.
S 824-006-B00
(3)
Put the vortex generator in the correct position (Fig. 401).
S 434-007-B00
(4)
Do the steps that follow to bond the vortex generator to the upper wing surface:
(a) Mix the base compound for the adhesive with the activator.
NOTE: Refer to the manufacturer's instructions for the
____
details.
(b)
Apply a thin, constant layer of the adhesive mixture to each mating surface.
(c)
Put the vortex generator on the upper wing surface immediately with sufficient pressure.
NOTE: A continuous bead of extruded adhesive can be seen
____
around the edges.
(d) Remove the unwanted adhesive around the edges of the vortex generator.
S 374-008-B00
(5) After the adhesive dries, apply paint to the wing surface if it is necessary.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
57-32-00
ALL ú ú B01 Page 404 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
AFT FAIRING PANEL, PYLON OVERWING - REMOVAL/INSTALLATION
___________________________________________________________
1. General_______
A. There are two tasks in this procedure:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 机翼 WINGS(23)