 C. If the F/O side stick is not locked with AP1 then AP2 engaged:
 (1) Replace the F/O side stick assembly (Ref. AMM TASK 27-92-41-000-001) and (Ref. AMM TASK 27-92-41-400-001).

 (2) If the fault continues:

 - replace the SOLENOID-PITCH & ROLL LOCK, F/O (12CA2) (Ref. AMM TASK 27-92-41-000-004) and (Ref. AMM TASK 27-92-41-400-004).

 (3) If the fault continues:

 - do a check of the wiring from the solenoid (12CA2) to the first terminal block, pin A/A to the terminal block 1871VT (Ref. ASM 22-85/01)

 - do a check and repair the wiring from the solenoid (12CA2) to the ground, pin A/B (Ref. ASM 22-85/01).

 


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page B281
 Aug 01/05R
 CES


 D. If the CAPT side stick is not locked with AP1 engaged only:

 (1) Replace the RELAY-STICK LOCK 1/CAPT (21CA) (Ref. IPC 22840802).

 (2) If the fault continues:


 - do a check and repair the wiring from the relay (21CA) to the first terminal block: . pin A/A1 to the terminal block 1871VT . pin A/A2 to the terminal block 1833VT . pin A/X1 to the terminal block 1831VT . pin A/X2 to the terminal block 1833VT (Ref. ASM 22-85/01).
 E. If the F/O side stick is not locked with AP1 engaged only:
 (1) Replace the RELAY-STICK LOCK 1/F/O (23CA) (Ref. IPC 22840802).

 (2) If the fault continues:


 - do a check and repair the wiring from the relay (23CA) to the first terminal block: . pin A/A1 to the terminal block 1871VT . pin A/A2 to the terminal block 1833VT . pin A/X1 to the terminal block 1831VT . pin A/X2 to the terminal block 1833VT (Ref. ASM 22-85/01).
 F. If the CAPT side stick is not locked with AP2 engaged only:
 (1) Replace the RELAY-STICK LOCK 2/CAPT (22CA) (Ref. IPC 22840802).

 (2) If the fault continues:


 - do a check and repair the wiring from the relay (22CA) to the first terminal block: . pin A/A1 to the terminal block 1871VT . pin A/A2 to the terminal block 1833VT . pin A/X1 to the terminal block 1840VT . pin A/X2 to the terminal block 1842VT (Ref. ASM 22-85/01).
 G. If the F/O side stick is not locked with AP2 engaged only:
 (1) Replace the RELAY-STICK LOCK 2/F/O (24CA) (Ref. IPC 22840802).

 (2) If the fault continues:


 - do a check and repair the wiring from the relay (24CA) to the first terminal block: . pin A/A1 to the terminal block 1871VT . pin A/A2 to the terminal block 1833VT . pin A/X1 to the terminal block 1840VT . pin A/X2 to the terminal block 1842VT (Ref. ASM 22-85/01).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page B282
 Aug 01/05R CES


 H. If the CAPT and F/O side sticks are not locked with AP1 then AP2 engaged:
 (1) Replace the C/B - AUTO FLT/STICK/LOCK (13CA) (Ref. ASM 22-84/08).

 (2) If the fault continues:


 - do a check and repair the wiring from the circuit breaker (13CA) to the first terminal block (Ref. ASM 22-85/01).
 J. If the CAPT and F/O side sticks are not locked with AP1 engaged only:
 (1) Replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).

 (2) If the fault continues:

 - replace the RELAY-STICK LOCK 1/CAPT (21CA) (Ref. IPC 22840802).

 (3) If the fault continues:

 - replace the RELAY-STICK LOCK 1/F/O (23CA) (Ref. IPC 22840802).

 (4) If the fault continues:


 - do a check of the wiring of the STICK LOCK COM and STICK LOCK MON signals from the FMGC1 to the first terminal block (Ref. ASM 22-85/01).
 (a) If there is no continuity:

 - repair the above wiring.

 (b) If there is continuity:


 - do a check for a short circuit and repair the wiring of the STICK LOCK COM and STICK LOCK MON signals from the FMGC1 to the relay (23CA) and the relay (21CA) (Ref. ASM 22-85/01).
 K. If the CAPT and F/O side sticks are not locked with AP2 engaged only:
 (1) Replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).

 (2) If the fault continues:


 - do a check of the wiring of the STICK LOCK COM and STICK LOCK MON signals from the FMGC2 to the first terminal block (Ref. ASM 22-85/01).
 (a) If there is no continuity:

 - repair the above wiring.

 (b) If there is continuity:


 - do a check for a short circuit and repair the wiring of the STICK LOCK COM and STICK LOCK MON signals from the FMGC2 to the relay (22CA) and the relay (24CA) (Ref. ASM 22-85/01).
 