- If the resistance values are in the specified limits: Install the ELAC2 (Ref. AMM TASK 27-93-34-400-001).
2 If the resistance values are in the specified limits:
_ a Repair the wiring of the SOL VLV1 signal from the
_ servocontrol (34CE4) to the ELAC2 (2CE2), from the pin C/K
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page A263
Feb 01/03R CES
to the pin AB/14K and from the pin C/L to the pin AE/14B (Ref. ASM 27-93/08):
b Install the ELAC2 (Ref. AMM TASK 27-93-34-400-001).
_
(c) If the resistance values are in the specified limits:
- See Para.(6).
(6) At the ELAC 2 receptacle, do a check of the insulation between pin AB/14K (pin AE/14B) and the ground.
NOTE : The resistance must be more than 100 Megohms.
____
(a) If the resistance is more than 100 Megohms:
- Replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
1 If the fault continues:
_ Replace the solenoid valve (Ref. AMM TASK 27-34-51-000-005) and (Ref. AMM TASK 27-34-51-400-004).
2 If the fault continues:
_ Replace the SERVO CTL-R ELEVATOR, OUTBD B (34CE4) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001).
3 do a check of the wiring from the ELAC2 (2CE2) COM part to the
_ ELAC2 COM part, from the pin AB/13K to the pin AB/13F (Ref. ASM 27-93/08):
a If the wiring is correct, see Para. 4_
_
b If the wiring is not correct:
_
- repair it
- install the ELAC2 (Ref. AMM TASK 27-93-34-400-001) 4 do a check of the wiring from the ELAC2 (2CE2) COM part to the
_ ELAC2 MON part, from the pin AB/13E to the pin AE/12D (Ref. ASM 27-93/08):
a If the wiring is correct, see Para. 5_
_
b If the wiring is not correct:
_
- repair it
- install the ELAC2 (Ref. AMM TASK 27-93-34-400-001) 5 do a check and repair the wiring from the ELAC2 (2CE2) MON
_ part pins AE/13B and AE/12C to the first terminal block (Ref. ASM 27-93/08):
6 Install the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-400-001).
_
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page A264
Feb 01/03R CES
(b) If the resistance is less than 100 Megohms:
- at the SERVO CTL-R ELEVATOR, OUTBD B (34CE4), do a check of the insulation of the solenoid valve between pin C/K (pin C/L) and the ground.
1_ If the resistance is less than 100 Megohms:
- Replace the solenoid valve (Ref. AMM TASK 27-34-51-000-005)
and (Ref. AMM TASK 27-34-51-400-004).
a Do again a check of the insulation of the solenoid valve
_ between pin C/K (pin C/L) and the ground. If the resistance is less than 100 Megohms: . Replace theSERVO CTL-R ELEVATOR, OUTBD B (34CE4) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001). . Replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
2 If the resistance is more than 100 Megohms:
_
a Repair the wiring of the solenoid valve signal from the
_ SERVO CTL-R ELEVATOR, OUTBD B (34CE4) to the ELAC-2 (2CE2).
b Replace theELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001)
_ and (Ref. AMM TASK 27-93-34-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page A265
Feb 01/03R
CES
Loss of the Signal of the Right Yellow Elevator-Servocontrol Position-Transducer by the ELAC 2
1. Possible Causes
_______________
- ELAC-2 (2CE2)
- wiring of the POS XDCR COM (ANI 2-2) signal from the ELAC 2 (2CE2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-814 Loss of the ACS1 Signal of the ELAC2 COM Side
27-90-00-810-815 Loss of the ACS1 Signal of the ELAC2 MON Side
27-90-00-810-816 Loss of the ACS1 of the ELAC2 COM and MON Sides
AMM 27-93-34-000-001 Removal of the ELAC (2CE1,2CE2)
AMM 27-93-34-400-001 Installation of the ELAC (2CE1,2CE2)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 3(42)