 (2) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).


 4. Fault Isolation
_______________
 A. If the tests give the maintenance message CHECK PRIORITY WIRING:
 - do the tests given in Para. 3. with only the ELAC1 engaged for the operational test of the side stick priority.
 (1) If the tests give the above maintenance message again:
 - replace the ELAC-1 (2CE1) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
 (a) If the fault continues:
 - do a check and repair the wiring of the STICK PRIORITY CAPT (DSI35) and STICK PRIORITY F/O (DSI36) signals from the ELAC1 (2CE1) COM part and MON part to the first terminal block (Ref. ASM 27-92/17).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page B245
 Aug 01/04R CES


 (2) If the tests do not give a maintenance message:
 - replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
 (a) If the fault continues:
 - do a check and repair the wiring of the STICK PRIORITY CAPT (DSI35) and STICK PRIORITY F/O (DSI36) signals from the ELAC2 (2CE2) COM part and MON part to the first terminal block (Ref. ASM 27-92/17).
 B. Do the tests given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page B246
 Aug 01/04R
 CES  Disagree between the Emergency Power Supply Discretes on the ELAC1 or ELAC2 or SEC1


 1. Possible Causes
_______________
 - ELAC-1 (2CE1)

 - SEC-1 (1CE1)

 - ELAC-2 (2CE2)

 - wiring of the LOSS OF NORMAL SPLY ON 2PP (DSI53) signal

 - wiring of the SEC1 IN EMERGENCY PWR SPLY (DSI3) signal


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 27-93-34-000-001 Removal of the ELAC (2CE1,2CE2)
 AMM 27-93-34-400-001 Installation of the ELAC (2CE1,2CE2)
 AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
 AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
 AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
 AMM 29-24-00-863-001 Pressurize the Yellow Hydraulic System with the

 Electric Pump
 AMM 29-24-00-864-001 Depressurize the Yellow Hydraulic System
 ASM 27-92/02

 3. Fault Confirmation
__________________
 A. Job Set-up
 (1) Pressurize the Yellow hydraulic system (Ref. AMM TASK 29-24-00-863-001).
 B. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/ELAC1/NORM/SPLY 15CE1 B11 49VU FLIGHT CONTROLS/SEC1/NORM/SPLY 21CE1 B08 121VU FLIGHT CONTROLS/THS ACTR/MOT1 19CE1 Q16
 Aug 01/04R CES

 C. Test


 (1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
 NOTE : Open the circuit breakers FLT CTL/ELAC1/NORM/SPLY (15CE1) and
____ FLT CTL/THS ACTR/MOT1 (19CE1) before you start the ground scanning.
 4. Fault Isolation
_______________
 A. If the BITE test gives the maintenance message EMER DISCRET DISAGREE:
 - do the test given in Para. 3. (ignore the NOTE): . with the ELAC1 engaged only . with the circuit breaker FLT CTL/ELAC1/NORM/SPLY (15CE1) open . with the circuit breaker FLT CTL/THS ACTR/MOT1 (19CE1) open
 (1) If the test gives the above maintenance message again:

 - replace the ELAC-1 (2CE1) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
 (a) If the fault continues:
 - do a check and repair the wiring of the LOSS OF NORMAL SPLY ON 2PP (DSI53) signal from the ELAC1 (2CE1) COM part and MON part to the first terminal block (Ref. ASM 27-92/02).

 (2) If the test does not give a maintenance message:


 - do the test given in Para. 3. (ignore the NOTE): . with the SEC1 engaged only . with the circuit breaker FLT CTL/THS ACTR/MOT1 (19CE1) open . with the circuit breaker FLT CTL/SEC1/NORM/SPLY (21CE1) open
 (a) If the test gives the maintenance message EMER DISCRET DISAGREE:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 3(73)