(2) Do the BITE test of the EFCS (Ground Scanning) (Ref. AMM TASK 27-96-00-740-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page A261
Feb 01/03R CES
4. Fault Isolation
_______________
A. If the tests give the maintenance message R B ELEV MODE VLV 34CE4:
(1) Remove the RELAY-THS MOT 3 INHIBITION 1 (51CE) and RELAY-THS MOT 3 INHIBITION 2 (52CE) (Ref. IPC 27920803).
(2) Do a check of the resistance and insulation of the relays.
NOTE : The resistance of the winding (pins X1 and X2) must be betwwen
____ 280 and 400 ohms; the insulation must be more than 500 KiloOhms.
(a) If the resistance and the insulation are in the specified limits:
- replace the RELAY-THS MOT 3 INHIBITION 1 (51CE) and/or RELAY-THS MOT 3 INHIBITION 2 (52CE) (Ref. IPC 27920803).
- replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001), (Ref. AMM TASK 27-93-34-400-001).
(b) If the resistance is more than the specified limits:
- replace the RELAY-THS MOT 3 INHIBITION 1 (51CE) and/or RELAY-THS MOT 3 INHIBITION 2 (52CE).
(c) If the resistance and the insulation are between the specified limits:
- install the RELAY-THS MOT 3 INHIBITION 1 (51CE) and RELAY-THS MOT 3 INHIBITION 2 (52CE)
- see Para (3).
(3) If the fault continues:
(4) Remove the ELAC2 (Ref. AMM TASK 27-93-34-000-001).
(5) At the ELAC2 receptacle, do a check of the resistance between the pin AB/14K and the pin AE/14B (Ref. ASM 27-93/08).
NOTE : The resistance must be between 40 and 100 Ohms.
____
(a) If the resistance is less than 40 Ohms:
- at the outboard elevator servocontrol (34CE4), do a check of the resistance of the solenoid valve between the pin C/K and the pin C/L (Ref. ASM 27-93/08).
NOTE : The resistance must be between 40 and 100 Ohms.
____
1 If the resistance values are out of the specified limits:
_ a Replace the solenoid valve of the servocontrol 34CE4 (Ref.
_ AMM TASK 27-34-51-000-005) and (Ref. AMM TASK 27-34-51-400-004).
Feb 01/03R CES
b Do again a check of the resistance of the solenoid valve
_ between the pin C/K and the pin C/L of the outboard elevator servocontrol (34CE4) (40 to 100 Ohms).
- If the resistance values are out of the specified limits: . Replace the SERVO CTL-R ELEVATOR, OUTBD B (34CE4) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001). . Replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
- If the resistance values are in the specified limits: Replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
2 If the resistance values are in the specified limits:
_ a Repair the wiring of the SOL VLV1 signal from the
_ servocontrol (34CE4) to the ELAC2 (2CE2), from the pin C/K to the pin AB/14K and from the pin C/L to the pin AE/14B (Ref. ASM 27-93/08):
b Replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001)
_ and (Ref. AMM TASK 27-93-34-400-001).
(b) If the resistance is more than 100 Ohms:
- at the outboard elevator servocontrol (34CE4), do a check of the resistance of the solenoid valve between the pin C/K and the pin C/L (Ref. ASM 27-93/08).
NOTE : The resistance must be between 40 and 100 Ohms.
____
1 If the resistance values are out of the specified limits:
_ a Replace the solenoid valve of the servocontrol 34CE4 (Ref.
_ AMM TASK 27-34-51-000-005) and (Ref. AMM TASK 27-34-51-400-004).
b Do again a check of the resistance of the solenoid valve
_ between the pin C/K and the pin C/L of the outboard elevator servocontrol (34CE4) (40 to 100 Ohms).
- If the resistance values are out of the specified limits: . Replace the SERVO CTL-R ELEVATOR, OUTBD B (34CE4) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001). . Install the ELAC2 (Ref. AMM TASK 27-93-34-400-001).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 3(41)