(4) If the fault continues:
(a) Replace the SERVO CTL-R ELEVATOR, INBD Y (34CE2) (Ref. AMM TASK 27-34-51-000-001) and (Ref. AMM TASK 27-34-51-400-001).
(5) If the fault continues:
(a) do a check of the wiring of the LVDT POS (ANI 3-2) signal from the ELAC 2 (2CE2) to the first terminal block (Ref. ASM 27-93/08).
- if there is continuity, see Para. (b)
- if there is no continuity, repair the above wiring.
(b) Repair the wiring of the POS RVDT MON signal from the transducer unit (49CE2) to the ELAC 2 (2CE2) (Ref. ASM 27-93/08).
B. Do the tests given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page A274
Feb 01/03R CES
Loss of the Right Yellow Elevator-Servocontrol Mode-Transducer by the ELAC 1
1. Possible Causes
_______________
- ELAC-1 (2CE1)
- wiring of the MODE XDCR (ANI 7-2) signal from the ELAC 1 (2CE1) MON part to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
27-90-00-810-811 Loss of the ACS1 Signal of the ELAC1 COM Side
27-90-00-810-812 Loss of the ACS1 Signal of the ELAC1 MON Side
27-90-00-810-813 Loss of the ACS1 of the ELAC1 COM and MON Sides
AMM 27-93-34-000-001 Removal of the ELAC (2CE1,2CE2)
AMM 27-93-34-400-001 Installation of the ELAC (2CE1,2CE2)
AMM 27-96-00-710-020 Operational Test of the Side Stick Assembly
(Activation for the BITE Test)
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
ASM 27-93/07
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the side stick assembly (activation for the BITE test) (Ref. AMM TASK 27-96-00-710-020).
(2) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
(a) If the ground scanning gives the maintenance message: ELAC1 OR WIRING FROM R Y ELEV MODE XDCR 34CE2
- refer to Para. Fault Isolation.
(b) If the ground scanning gives at least two maintenance messages of the two lists below: First list:
- ELAC1 COM OR WIRING FROM THS ACTR XDCR2 9CE
- ELAC1 OR WIRING FROM L B ELEV POS XDCR 34CE3
- ELAC1 OR WIRING FROM R B ELEV POS XDCR 34CE4 Second list:
- ELAC1 MON OR WIRING FROM THS ACTR XDCR2 9CE
- ELAC1 OR WIRING FROM L ELEV POS MON XDCR
- ELAC1 OR WIRING FROM R ELEV POS MON XDCR
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page A275
Feb 01/03R CES
- ELAC1 OR WIRING FROM L G ELEV MODE XDCR 34CE1
- ELAC1 OR WIRING FROM R Y ELEV MODE XDCR 34CE2
1_ First case:
Combination of maintenance messages of the first list, do this
trouble shooting procedure (Ref. TASK 27-90-00-810-811).
2_ Second case:
Combination of maintenance messages of the second list, do
this trouble shooting procedure (Ref. TASK 27-90-00-810-812).
3_ Third case:
Combination of maintenance messages of the first and second
lists, do this trouble shooting procedure (Ref. TASK 27-90-00-
810-813).
4. Fault Isolation
_______________
A. If the test gives the maintenance message: ELAC1 OR WIRING FROM R Y ELEV MODE XDCR 34CE2
- replace the ELAC-1 (2CE1) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the MODE XDCR (ANI 7-2) signal from the ELAC 1 (2CE1) MON part to the first terminal block (Ref. ASM 27-93/07).
B. Do the tests given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page A276
Feb 01/03R
CES Failure of the Right Yellow Elevator Servocontrol Actuator Solenoid valve
CAUTION : DO NOT SWAP FLIGHT CONTROL COMPUTERS. IF THERE IS A SHORT CIRCUIT,
_______ YOU WILL CAUSE DAMAGE TO A SERVICEABLE COMPUTER WHEN YOU SWAP THEM.