B. If the BITE test gives the maintenance message: IR2 or BUS3 to ELAC1 and on the upper ECAM DU, the INOP SYS CAT 3 DUAL warning comes into view:
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
(a) Remove the ADIRU2.
(b) Do a check of the wiring of the INERTIAL REFERENCE OUTPUT BUS 3 from the ADIRU2 (1FP2) to the first terminal block.
1 If there is no continuity:
_
a Repair it.
_
b Install the ADIRU2.
_
2 If there is continuity:
_
a Install the ADIRU2.
_ b Do the trouble shooting procedure that follows (Ref. TASK
_
31-32-00-810-934).
C. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page A209
May 01/99R
CES Loss of the IR 2 BUS 2 for the ELAC 2
1. Possible Causes
_______________
- ELAC-2 (2CE2)
- wiring of the DGI 03 signal from the ELAC 2 (2CE2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 27-93-34-000-001 Removal of the ELAC (2CE1,2CE2)
AMM 27-93-34-400-001 Installation of the ELAC (2CE1,2CE2)
R AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) ASM 27-92/52
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the BITE test gives the maintenance message:
ELAC2 MON OR BUS2 FROM IR2
- replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the DGI 03 signal from the ELAC 2 (2CE2) to the first terminal block, MON part only (Ref. ASM 27-92/52).
B. Do the test given in Para. 3.
Loss of the IR 3 BUS 3 for the ELAC 1
1. Possible Causes
_______________
- ELAC-1 (2CE1)
- wiring of the DGI 03 signal from the ELAC 1 (2CE1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 27-93-34-000-001 Removal of the ELAC (2CE1,2CE2)
AMM 27-93-34-400-001 Installation of the ELAC (2CE1,2CE2)
R AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) ASM 27-92/50
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the BITE test gives the maintenance message:
ELAC1 COM OR BUS3 FROM IR3
- replace the ELAC-1 (2CE1) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the DGI 03 signal from the ELAC 1 (2CE1) to the first terminal block COM part only (Ref. ASM 27-92/50).
B. Do the test given in Para. 3.
Loss of the IR 3 BUS 2 for the ELAC 2
1. Possible Causes
_______________
- ELAC-2 (2CE2)
- wiring of the DGI 02 signal from the ELAC 2 (2CE2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 3(21)