R (2) Do a check of the resistance of the relay between pin X1 and X2.
R (a) If the resistance is less than 280 ohms:
R - install a new F/O W ANN SPLY relay (42CE2) (Ref. IPC 27920803)
R - replace the FCDC-1 (3CE1) (Ref. AMM TASK 27-95-34-000-001)
R (Ref. AMM TASK 27-95-34-400-001).
R (b) If the resistance is more than 400 ohms
R - install a new F/O W ANN SPLY relay (42CE2) (Ref. IPC 27920803)
R - see Para. (3).
R (c) If the resistance is between 280 and 400 ohms:
R - install the F/O W ANN SPLY relay (42CE2)
R - See Para. (3).
R (3) If the fault continues:
R (a) Replace the FCDC-1 (3CE1) (Ref. AMM TASK 27-95-34-000-001) (Ref.
R AMM TASK 27-95-34-400-001).
R (4) If the fault continues:
R (a) Replace the RELAY-F/O W ANN SPLY (42CE2) (Ref. IPC 27920803).
R (5) If the fault continues:
R (a) Do a check of the wiring between the F/O W ANN SPLY relay (42CE2)
R pin X2 and the FCDC-1 (3CE1) (Ref. ASM 27-95/04).
R (b) Do a check of the wiring between the F/O W ANN SPLY relay (42CE2)
R pin A1 and the ground.
R (c) Do a check of the wiring between the F/O W ANN SPLY relay (42CE2)
R pin X1 and the first terminal block.
R B. If, during the test, with circuit breaker 20CE2 opened (circuit breaker
R 20CE1 closed):
R - the CAPT legend of the SIDE STICK PRIORITY annunciator does not come on
R when you move the F/O side stick:
R (1) Replace the FCDC-1 (3CE1) (Ref. AMM TASK 27-95-34-000-001) (Ref. AMM
R TASK 27-95-34-400-001).
R (2) If the fault continues:
R (a) Replace the BOARD-ANN LT TEST & INTFC (2LP) (Ref. IPC 33140803).
R (3) If the fault continues:
R (a) Replace the RELAY-CAPT G ANN SPLY (42CE3) (Ref. IPC 27920803).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-95-00∞∞∞∞∞∞∞∞∞∞Page 225
May 01/99 CES
R (4) If the fault continues:
R (a) Do a check of the wiring between the ANN LT TEST & INTFC BOARD
R pin 23 and the FCDC 1 (3CE1) (Ref. ASM 27-95/04).
R (b) Do a check of the wiring between pin 3 and pin 25 of the ANN LT
R TEST & INTFC board (2LP).
R (c) Do a check of the wiring between the ANN LT TEST & INTFC board
R (2LP) pin 4 and the first terminal block.
R (d) Do a check of the wiring between the ANN LT TEST & INTFC board
R (2LP) pin 22 and the CAPT G ANN SPLY relay (42CE3) pin A3.
R C. If during the test, with circuit breaker 20CE2 open (circuit breaker
R 20CE1 closed):
R - the red arrow of the CAPT SIDE STICK PRIORITY annunciator does not come
R on when you push the F/O takeover and priority pushbutton switch:
R (1) Replace the FCDC 1 (3CE1) (Ref. AMM TASK 27-95-34-000-001) (Ref. AMM
R TASK 27-95-34-400-001).
R (2) If the fault continues:
R (a) Replace the BOARD-ANN LT TEST & INTFC (2LP) (Ref. IPC 33140803)
R (3) If the fault continues:
R (a) Replace the RELAY-CAPT W ANN SPLY (42CE1) (Ref. IPC 27920803).
R (4) If the fault continues:
R (a) Do a check of the wiring between the ANN LT TEST & INTFC board
R (2LP) and the FCDC 1(3CE1) (Ref. ASM 27-95/04).
R (b) Do a check of the wiring between the ANN LT TEST & INTFC board
R (2LP) pin 4 and the first terminal block.
R (c) Do a check of the wiring between the ANN LT TEST & INTFC board
R (2LP) pin 1 and the CAPT W ANN SPLY relay (42CE1) pin A3.
R D. If during the test, with circuit breaker 20CE2 open (circuit breaker
R 20CE1 closed):
R - the F/O legend of the SIDE STICK PRIORITY annunciator does not come on
R when you move the CAPT side stick:
R (1) Remove the RELAY-F/O G ANN SPLY (42CE4).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-95-00∞∞∞∞∞∞∞∞∞∞Page 226
May 01/99 CES
R (2) Do a check of the resistance of the relay between pin X1 and X2.
R (a) If the resistance is less than 280 ohms:
R - install a new F/O G ANN SPLY relay (42CE4) (Ref. IPC 27920803)
R - replace the FCDC-1 (3CE1) (Ref. AMM TASK 27-95-34-000-001)
R (Ref. AMM TASK 27-95-34-400-001).
R (b) If the resistance is more than 400 ohms:
R - install a new F/O G ANN SPLY relay (42CE4) (Ref. IPC 27920803)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 3(149)