 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
 4. Fault Isolation
_______________
 A. If the BITE test gives the maintenance message:
 SEC3 MON OR BUS5 FROM FCDC1

 - replace the SEC-3 (1CE3) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM TASK 27-94-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the DGI 10 signal from the SEC3 (1CE3) to the first terminal block (Ref. ASM 27-95/02).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞27-94-00∞∞∞∞∞∞∞∞∞∞Page A234
 Feb 01/03R
 CES R Loss of the FCDC 2 BUS 6 Signal for the SEC 2


 1. Possible Causes
_______________
 - SEC-2 (1CE2)

 - wiring of the DGI 10 signal from the SEC2 (1CE2) to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
 AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
 AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
 ASM 27-95/03

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
 4. Fault Isolation
_______________
 A. If the BITE test gives the maintenance message:
 SEC2 MON OR BUS6 FROM FCDC2

 - replace the SEC-2 (1CE2) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM TASK 27-94-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the DGI 10 signal from the SEC2 (1CE2) to the first terminal block (Ref. ASM 27-95/03).
 B. Do the test given in Para. 3.


R Loss of the FCDC 2 BUS 6 Signal for the SEC 3
 1. Possible Causes
_______________
 - SEC-3 (1CE3)

 - wiring of the DGI 10 signal from the SEC3 (1CE3) to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
 AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
 AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
 ASM 27-95/03

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
 4. Fault Isolation
_______________
 A. If the BITE test gives the maintenance message:
 SEC3 MON OR BUS6 FROM FCDC2

 - replace the SEC-3 (1CE3) (Ref. AMM TASK 27-94-34-000-001) and (Ref. AMM TASK 27-94-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the DGI 10 signal from the SEC3 (1CE3) to the first terminal block (Ref. ASM 27-95/03).
 B. Do the test given in Para. 3.


 Loss of the ELAC 1 COM BUS 1 Signal for the SEC 1
 1. Possible Causes
_______________
 - SEC-1 (1CE1)

 - wiring of the DGI 09 signal from the SEC1 (1CE1) COM part and MON part to the first terminal block

 - wiring of the DSI 21 signal from the SEC1 (1CE1) COM part and MON part to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 27-94-34-000-001 Removal of the SEC (1CE1,1CE2,1CE3)
 AMM 27-94-34-400-001 Installation of the SEC (1CE1,1CE2,1CE3)
 AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
 ASM 27-92/49
 ASM 27-92/50

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the EFCS (ground scanning) (Ref. AMM TASK 27-96-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message: R ELAC1 COM BUS 1
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn