- replace the SSTU-ROLL CTL, F/O (4CE2) (Ref. AMM TASK 27-92-41-000-002) and (Ref. AMM TASK 27-92-41-400-002).
(b) On the panel 131VU, on the SIDE STICK PRIORITY/CAPT annunciator light, if the green CAPT legend does not come on:
1_ If the fault continues:
- replace the SSTU-PITCH CTL, F/O (4CE4) (Ref. AMM TASK 27-92-
41-000-002) and (Ref. AMM TASK 27-92-41-400-002).
- replace the SSTU-ROLL CTL, CAPT (4CE1) (Ref. AMM TASK 27-92-41-000-002) and (Ref. AMM TASK 27-92-41-400-002).
1 If the fault continues:
_
- replace the SSTU-PITCH CTL, CAPT (4CE3) (Ref. AMM TASK 27-92-41-000-002) and (Ref. AMM TASK 27-92-41-400-002).
D. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 051-099, 101-105, 151-199, ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page B273
201-214, Aug 01/05R
CES TASK 27-93-00-810-937
Failure of the Roll Side Stick Transducer Unit Potentiometer or of the R G
Aileron Servocontrol
1. Possible Causes
_______________
- SSTU-ROLL CTL, CAPT (4CE1)
- SSTU-ROLL CTL, F/O (4CE2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
27-10-00-810-819 Failure of the Right Green Aileron Servo Control Position Transducer 27-10-00-810-820 Loss of the Right Green Aileron Position Transducer Signal for the ELAC 1 27-10-00-810-821 Loss of the Servovalve Signal for the Right Green Aileron Servo Control 27-10-00-810-823 Failure of the Right Green Aileron Servo Control Servovalve 27-10-00-810-824 Failure of the Right Green Aileron Servo Control Solenoid Valve 27-10-00-810-825 Loss of the Right Aileron Changeover Signal for the
ELAC 1 AMM 27-92-41-000-002 Removal of the Transducer Units (4CE1,4CE2,4CE3,4CE4) AMM 27-92-41-400-002 Installation of the Transducer Units
(4CE1,4CE2,4CE3,4CE4)
AMM 29-10-00-863-001 Pressurize the Green Hydraulic System
3. Fault Confirmation
__________________
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault Isolation
_______________
A. With Green hydraulic system pressurized (Ref. AMM TASK 29-10-00-863-001), on the F/CTL page of the Lower ECAM DU, if the R AIL G servocontrol indication is amber:
- do this trouble shooting procedure (Ref. TASK 27-10-00-810-819).
(1) On the panel 23VU, release and push the FLT CTL/ELAC 1 pushbutton switch.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞27-93-00∞∞∞∞∞∞∞∞∞∞Page B274
Aug 01/05 CES
(2) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TASK 27-10-00-810-820).
(3) On the panel 23VU, release and push the FLT CTL/ELAC 1 pushbutton switch.
(4) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TASK 27-10-00-810-821).
(5) On the panel 23VU, release and push the FLT CTL/ELAC 1 pushbutton switch.
(6) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TASK 27-10-00-810-823).
(7) On the panel 23VU, release and push the FLT CTL/ELAC 1 pushbutton switch.
(8) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TASK 27-10-00-810-824).
(9) On the panel 23VU, release and push the FLT CTL/ELAC 1 pushbutton switch.
(10) On the upper ECAM DU, if the F/CTL AIL SERVO FAULT warning stays in view:
- do this trouble shooting procedure (Ref. TASK 27-10-00-810-825).
B. With Green hydraulic system pressurized (Ref. AMM TASK 29-10-00-863-001), on the F/CTL page of the lower ECAM DU, if the R AIL G servocontrol indication is not amber:
- replace the SSTU-ROLL CTL, CAPT (4CE1) and SSTU-ROLL CTL, F/O (4CE2) (Ref. AMM TASK 27-92-41-000-002) and (Ref. AMM TASK 27-92-41-400-002).
Failure of the Roll Side Stick Transducer Unit Potentiometer
1. Possible Causes
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 飞行操纵 3(83)