(2)
AMM 27-81-00/201, Leading Edge Slat System
B.
Access
(1)
Location Zone
621 Leading Edge to Front Spar (Right)
(2)
Access Panel
621GB Fueling Station Door (Right)
C.
Procedure
S 864-002
(1)
Open this circuit breaker on the main power distribution panel, P6, and attach a DO-NOT-CLOSE tag:
(a)
6E5, FUELING CONTROL
S 864-003
(2)
Open this circuit breaker on the APU external power panel, P34, and attach a DO-NOT-CLOSE tag:
(a)
34A11, FLNG CONT
S 044-035
WARNING: DO THE DEACTIVATION PROCEDURE FOR THE LEADING EDGE SLATS OR
_______ MOVE ALL PERSONS AND EQUIPMENT AWAY FROM THE LEADING EDGE SLATS. THE SLATS CAN MOVE QUICKLY AND CAUSE INJURY OR DAMAGE.
(3)
Do the Deactivation of the Leading Edge Slats procedure (AMM 27-81-00/201).
(4)
Open the fueling station door, 621GB (AMM 06-44-00/201).
S 034-037
(5)
Disconnect the wiring leads of the fueling power control switch from the airplane wiring leads (View A-A).
S 014-036
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-14
ALL ú ú 01 Page 401 ú Sep 28/00
A
757
MAINTENANCE MANUAL
DOOR SWITCH, S346
FWD
GROUNDING LUG (EXAMPLE)
FUELING STATION
MAGNETIC
BRACKET
DOOR
INBDFWD
FUELING POWER CONTROL SWITCH, S346
Fueling Power Control Switch Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
ú ALL ú ú 01
28-21-14
Page 402
ú May 28/99
E46661
A
757 MAINTENANCE MANUAL
S 034-038
(6)
Remove the screws that attach the fueling power control switch to the bracket.
S 024-039
(7)
Remove the fueling power control switch.
TASK 28-21-14-424-040
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 燃油 CHAPTER 28 - FUEL 2(91)