B.
Access
(1)
Location Zones 543 Surge Tank - Rib No. 21 to No. 23 (Left) 643 Surge Tank - Rib No. 21 to No. 23 (Right)
(2)
Access Panels
543BB Surge Tank Door (Left)
643BB Surge Tank Door (Right)
C.
Procedure
S 014-011
(1)
Remove the surge tank access door, 543BB or 643BB
(AMM 28-11-03/401).
S 034-012
(2)
Remove the housing bolts and washers from the surge tank access door (18 locations).
S 024-002
(3)
Remove the housing of the vent flame arrestor and the tube that attaches to it.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-13-05
ALL ú ú 01 Page 401 ú May 28/99
A
757
MAINTENANCE MANUAL
VENT FLAME ARRESTOR INSTALLATION
SEE A
NUT PLATE
VENT FLAME ARRESTOR
INSTALLATION
LOWER WING SURFACESEE A RUBBER SEAL
A
HOUSING OF THE VENT FLAME ARRESTOR
SURGE TANK MOUNTING
A
ACCESS DOOR BOLT TUBE (EXAMPLE)
VENT FLAME ARRESTOR
BOLT AND WASHER
(12 LOCATIONS) INSTALLATION GASKOSEAL
A
VENT FLAME ARRESTOR
HOUSING OF THE VENT FLAME ARRESTOR
HOUSING BOLT
(18 LOCATIONS)
WASHER (18 LOCATIONS)
SURGE TANK ACCESS DOOR
A-A
Surge Tank Vent Flame Arrestor Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-13-05
ALL ú ú 01 Page 402 ú Sep 28/01
A
757 MAINTENANCE MANUAL
S 034-003
(4)
Remove the bolts and the washers (12 locations) that hold the vent flame arrestor to the housing of the vent flame arrestor.
S 034-020
(5)
Remove the tube and the vent flame arrestor.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 燃油 CHAPTER 28 - FUEL 2(33)