(2)
AMM 27-81-00/201, Leading Edge Slat System
B.
Access
(1)
Location Zone
621 Leading Edge to Front Spar (Right)
(2)
Access Panel
621GB Fueling Station Door (Right)
C.
Procedure
S 864-002
(1)
Open these circuit breakers on the main power distribution panel, P6, and attach DO-NOT-CLOSE tags:
(a)
6E4, FUELING QTY
(b)
6E5, FUELING CONT
S 864-003
(2)
Open these circuit breakers on the overhead circuit breaker panel, P11, and attach DO-NOT-CLOSE tags:
(a)
11C34, FUEL QTY 1 OR FUEL QTY L
(b)
11L19, FUEL QTY 2 OR FUEL QTY R
S 864-004
(3)
Open these circuit breakers on the APU external power panel, P34, and attach DO-NOT-CLOSE tags:
(a)
34A10, FUEL QTY
(b)
34A11, FLNG CONT
S 864-005
WARNING: DO THE DEACTIVATION PROCEDURE FOR THE LEADING EDGE SLAT
_______ (AMM 27-81-00/201). FAILURE TO DO THE DEACTIVATION OF THE LEADING EDGE SLAT PROCEDURE COULD CAUSE INJURY TO PERSONS IF THE SLATS MOVE ACCIDENTALLY.
(4) Do the deactivation procedure for the leading edge slats (AMM 27-81-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-08
ALL ú ú 02 Page 401 ú Sep 28/00
A
757
MAINTENANCE MANUAL
1 THE UNITS ARE IN KGS OR LBS
Fueling Control Panel Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-08
ALL ú
ú 01 Page 402
ú May 28/99
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 燃油 CHAPTER 28 - FUEL 2(82)