(4)
Fueling Modes
(a)
Automatic Mode With Electrical Power
1) During automatic mode of pressure fueling, the FQIS processor controls the fueling process. The FQIS processor monitors the quantity of fuel in each fuel tank constantly. The FQIS processor stops the fueling operation when the fuel tanks are full, have reached the selected fuel quantity, or if an unknown accuracy condition is detected by the FQIS processor.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-00
ALL ú ú 01 Page 11 ú Jan 28/02
A
757
MAINTENANCE MANUAL
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-00
ALL ú ú 01 Page 12 ú Jan 28/02
ABC
DEFGH
J
K
L
MN
PR
DOOR RELAY DOOR SWITCH
Pressure Fueling Schematic (Example)Figure 6 (Sheet 1)
ABC
D
E
F
G
H
J
K
L
M
N
P
R
Pressure Fueling Schematic (Example)Figure 6 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-21-00
ALL ú ú 01 Page 13 ú Jan 28/02
A
757
MAINTENANCE MANUAL
2) Whenever an unknown accuracy condition occurs, the FQIS processor will close the fueling shutoff valve(s) for the applicable fuel tank. In addition, the failure of a single FQIS processor channel causes one of the two fueling shutoff valves in the center fuel tank to close.
3) Selecting the desired fuel quantity on the LOAD SELECT control thumbwheels and pressing the SET switches for the tanks to be fueled places the system in the automatic mode. The quantity selected is shown in the load select display (lower LCD). With the fuel truck nozzles attached to the fueling adapters (set in the fuel mode) and the fueling valve switches selected to FUEL, fuel enters the fueling manifold and into the selected tank through the corresponding fueling shutoff valve. The FQIS processor closes the fueling shutoff valves when the selected quantity is reached or the fuel tanks are full.