• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-05-24 14:56来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Flap circuit-breaker opens when the flaps stop at the chosen position.  Short to ground in the wires to the electrical control unit from the related indication micro-switch.  Do an insulation test between each wire and ground. Repair or replace defective wires. 

Doc # 6.02.01 Page 101
Rev. 4 09 Jan 2003

27-50-00
AMM

DA 40 Series

Trouble  Possible Cause  Repair 
Flap circuit-breaker opens when the flaps have moved only a short distance from the UP setting.  Short to ground in the wires to the electrical control unit from micro-switch 1.  Do an insulation test between each wire and ground. Repair or replace defective wires. 
Flap circuit-breaker opens when the flaps have moved only a short distance from the LDG setting.  Short to ground in the wires to the electrical control unit from micro-switch 4.  Do an insulation test between each wire and ground. Repair or replace defective wires. 
Flaps move slowly.  Airplane electrical system voltage low. Flap motor defective. Flap actuator defective.  Do a test of the airplane electrical system voltage. Do a test for 14 V at the motor with flaps selected. If there is 14 V at the motor, replace the actuator. Examine the actuator. If you find damage, then replace the flap actuator. 
Flaps do no not align with the wing trailing edge.  Flaps extended at too high airspeed.  Examine the flap system. Replace damaged parts. Adjust the system. 
Flaps will not move to  Micro-switch 4 defective.  Replace the micro-switch. 
LDG position. Flaps move  Open circuit in the micro-switch 4  Do a continuity test of the 
to T/O and UP correctly.  wiring.  wiring. Repair or replace the defective wire. 
Flaps will not move to UP  Micro-switch 1 defective.  Replace the micro-switch. 
position. Flaps move to  Open circuit in the micro-switch 1  Do a continuity test of the 
T/O and LDG correctly.  wiring.  wiring. Repair or replace the defective wire. 

27-50-00
Flight Controls
AMM

DA 40 Series

Trouble  Possible Cause  Repair 
No LDG indication when the flaps are in the LDG position. Flaps will not move from LDG to T/O. Flaps move from LDG to UP correctly.  Micro-switch 5 defective. Open circuit in the micro-switch 5 wiring.  Replace the micro-switch. Do a continuity test of the wiring. Repair or replace the defective wire. 
No UP indication when the flaps are in the UP position. Flaps will not move from UP to T/O. Flaps move from UP to LDG correctly.  Micro-switch 2 defective. Open circuit in the micro-switch 2 wiring.  Replace the micro-switch. Do a continuity test of the wiring. Repair or replace the defective wire. 
No T/O indication when the flaps are in the T/O position. Flaps move to all positions correctly.  Micro-switch 3 defective. Open circuit in the micro-switch 3 wiring.  Replace the micro-switch. Do a continuity test of the wiring. Repair or replace the defective wire. 
Flap circuit-breaker opens at the end of down movement.  Micro-switch 4 defective.  Replace the micro-switch. 
Flap circuit-breaker opens at the end of up movement.  Micro-switch 1 defective.  Replace the micro-switch. 
LDG LED stays on when the flaps are not in the LDG position. The other indications operate correctly.  Micro-switch 5 defective.  Replace the micro-switch. 
UP LED stays on when the flaps are not in the UP position. The other indications operate correctly.  Micro-switch 2 defective.  Replace the micro-switch. 

27-50-00
AMM

Trouble  Possible Cause  Repair 
T/O LED stays on when the flaps are not in the T/O position. The other indications operate correctly.  Micro-switch 3 defective.  Replace the micro-switch. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:钻石40飞机维护手册 DA 40 SERIES AMM 3(22)