NVG
SIDE CONTROL PANEL
AB0386
SA
Figure 4-24. Medical Control Panels
LIFEPAK 10 MOUNT
4.12.9 Medical IV Bags. Provisions for IV bags are in-stalled on the cabin ceiling. Flow adjustment and IV bag replacement are accomplished by the medical attendants.
4.12.10 Interior Lighting System. Lighting controls are located on the left and right overhead control panels (Figure 4-24). The controls on each panel affect the lighting
FIRST AID KIT
system for that side of the aircraft only. The lighting system
is interlocked through the pilot’s CABIN DOME LT switch. When the pilot selects BLUE on the pilots CABIN DOME LT switch, the medical cabin overhead and panel lighting changes to blue/green and is controllable from the cabin, dimmer controls are still functional. Side lighting is
FIRE BOTTLE
turned off. If the pilot places the CABIN DOME LT switch to WHITE, the medical cabin lighting control is enabled in WHITE light and is controlled from the cabin, dimmer controls are still functional. If the pilot places the CABIN LIGHTING switch to OFF the medical cabin lighting is disabled.
4.12.10.1 Panel Overlay Lighting. Panel lighting is turned on with the CEILING lights ON-OFF switch on the right side of the overhead control panel. Both ceiling lights and panel overlay lighting are turned on and off to-
gether. Brightness is controlled separately. The CEILING CTR and CEILING AFT knobs control the brightness of the ceiling lights and the PANEL knob controls the bright-ness of the panel overlay lighting.
CRASH
AXE INFECTIOUS WASTEAPU AND BIOHAZARDACCUMULATOR MATERIALPUMP HANDLE
AB0387
SA
Figure 4-25. Medical Cabinet
drawer for convenient disposal of materials. Electrical power (115 VAC 60Hz) and space provisions for PROPAQ portable patient monitors and LIFEPAK 10 de.brillator monitors are included. The upper cabinet also includes the status panel for the molecular sieve oxygen generating sys-tem (MSOGS). Hooks are provided on the side of the cabi-net to stow a .re extinguisher, .rst aid kit, crash axe and a accumulator pump (APU) handle. An access plate in the base of the medical cabinet can be removed to provide access to the aircraft computers. Circuit breakers for the AC-DC converter and oxygen panel displays are located on the underside of the oxygen status panel.
1.
Place the CEILING ON-OFF switch to ON. The ceiling and panel overlay lights illuminate.
2.
Turn the PANEL knob clockwise to increase panel light brightness, counter clockwise to de-crease panel light brightness.
3.
Place the CEILING ON-OFF switch to OFF. The ceiling and panel overlay lights turn off.
4.12.10.2 Ceiling Lighting. The CABIN DOME LT switch must be in the WHITE position to operate the over-head lights in the white light mode. If the CABIN DOME LT switch is in the BLUE position, the overhead lights will be blue/green. If the pilots lighting control switch is OFF the overhead lights will not operate.
1.
Place the CEILING ON-OFF switches to ON.
2.
Adjust the CEILING CTR and CEILING AFT knobs on the left and right overhead con-trol panels to obtain desired intensity. Turn
SA
clockwise to increase intensity and counter clockwise to decrease intensity.
3. Place the CEILING ON-OFF switches on the left and right overhead control panels to OFF. All ceiling lights and panel overlay lighting turns off. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:UH-60Q 直升机技术手册 直升机操作手册 1(149)