Ensure the backrest and headrests are secured in place.

4.12.4 Litter Platforms. There are a total of four plat-forms installed in the aircraft, two at each station (Figure 4-23). The platforms provide a loading surface for a patient strapped to a litter. The litter is secured to the platform by means of a locking device mounted in the end of the plat-form and two restraint belts. The platforms attach to the support rods and are raised, lowered, or tilted by the lift mechanism. The platforms are similar in construction, with the exception that the upper platform may be recon.gured to provide seating for three ambulatory patients.
4.12.5 MEDEVAC Seats Installation. Three crew seats, two located in the aft cabin area and one located in the center between the forward medical stations, are pro-vided for the crew chief/medical attendants. Each seat swivels 360 degrees and is T track mounted, which allows the seats to move fore and aft for better access to the pa-
OVERHEAD LIGHT
AMBULATORY
OVERHEAD

FIXTURE SEAT TRACK
SEAT
CONTROL PANEL

 

 


LEFT SIDE CONTROL PANEL

 

 

PLATFORM SA
tients. Each seat contains a headrest, which attendant re-straints provided by a lap safety belt which connects to a shoulder harness. Lift forward (upper) knob to swivel, aft (lower) knob to move fore and aft.
4.12.6 Medical Control Panels. The Medical Control Panels are located on each side of the aircraft (doorpost panels), and on the ceiling (overhead panel) (Figure 4-24) to provide full access to medical controls by medical per-sonnel. The side control panels contain covered 115 VAC 60 Hz electrical outlets and controls for the litter lifts, suc-tion systems, and oxygen system. Lighted Indicators are ANVIS (Aviators Night Vision Imaging System) compat-ible and have the ability to be dimmed. Control and func-tions are further de.ned:
CONTROLS/ FUNCTION
INDICATORS

OXYGEN
Regulator Control Regulates oxygen .ow.
DISS/Barbed outlet Connection for oxygen outlet hose.
CONTROLS/  FUNCTION 
INDICATORS 
Quick Disconnect  Quick disconnect connection for 
Oxygen Outlet  the Chemetron compatible oxygen 
hose. 
LITTER LIFTS 
switches 
UPPER  Moves the forward and aft end of 
PLATFORM  the upper litter platform up or 
FWD UP  down. 
DOWN and 
AFT UP 
DOWN 
LOWER  Moves the forward and aft end of 
PLATFORM  the lower litter platform up or 
FWD UP  down. 
DOWN and 
AFT UP 
DOWN 
EMERGENCY 
STOP 


MEDICAL 
CABINET 
AMBULATORY 
PATIENT’S 
SEAT 

MEDICAL ATTENDANT’S SEAT 
LITTER PLATFORM  LITTER LIFT  SA AB0384 
Figure 4-22. Ambulatory Seat Arrangement 
DUAL LIFTS  MEDICAL INTERIOR CIRCUIT BREAKER PANEL  DUAL LIFTS 
PRIMARY PATIENT 
PRIMARY PATIENT  AMBULATORY PATIENT LITTER PLATFORM 
SECONDARY PATIENTS  LIGHTS LITTER PLATFORM 
SA AB0385 
Figure 4-23. Litter Platform


CONTROLS/ FUNCTION INDICATORS
STOP Stops motion of all litter platforms.

RUN  Allows normal platform operation. 
SEAT OVERRIDE  When ON disables the LITTER 
DISABLE  LIFTS switches  on  the overhead 
ON  OFF  console.  When  OFF,  LITTER 
LIFTS  switches  on  overhead 

console are enabled.

Upper lift Provides reference for positioning reference mark upper litter.
Lower lift Provides reference for positioning reference mark lower litter.
 