• 热门标签

当前位置: 主页 > 航空资料 > 飞行资料 >

时间:2011-04-23 09:57来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

NOTE 
Fuel tanks selector and quantity 
indicators are also used in 
conjunction with INCR-DECR 
switch when initializing fuel 
quantity of tanks. 
OUTBD  Total pounds of fuel remaining in 
outboard pair of tanks. 
INBD  Not used. 
TOTAL  Pounds of fuel remaining in all 
external extended range tanks. 
CAL  Adjusts K factor of .ow switch on 
AUXILIARY FUEL 
MANAGEMENT panel. 
INCR switch  Increases setting of digital readout 
position  to adjust for fuel remaining in tanks 
selected by fuel tank selector. 
DECR switch  Decreases setting of digital readout 
position  to adjust for fuel remaining in tanks 
selected by fuel tank selector. 
STATUS button  Resets AUX FUEL caution light 
and stores condition of NO FLOW 
and EMPTY indicators. 

CONTROL/
INDICATOR

TEST
DEGRADED light
EXTERNAL
*RIGHT NO FLOW light
*INBD EMPTY light
*OUTBD EMPTY light
*LEFT NO FLOW light
*INBD EMPTY light
*OUTBD
EMPTY

light
VENT SENSOR
*OVFL
FUNCTION
Checks display and indicator lights. Performs memory checksum, displays 8 sequentially in each digital display. Veri.es that temperature probe is connected; veri.es that .ow meter is connected; performs trial calculation based on a known temperature and .ow meter input, compares it with a known good value, and displays setting of fuel density switch. At completion of test, GOOD or error code will be displayed (Table 4-2).
Error in critical function has occurred. Error code will be displayed as shown under TEST. Only E02 error will allow microprocessor to clear failure code and regain fuel remaining information by doing two self-tests.
Fuel .ow does not exit from selected right tank.
Not used.
Right outboard tank fuel exhausted.
Fuel .ow does not exit from selected left tank.
Not used.
Left outboard tank fuel exhausted.
Detects the presence of fuel on the vent thermistor.
Indicates fuel venting overboard.
Change 2 4-41

CONTROL/ FUNCTION
INDICATOR

NOTE
Illumination of this capsule on the Fuel Management Panel will cause illumination of the AUX FUEL caution legend and the MASTER CAUTION light. Pushing the STATUS button will reset the NO FLOW, AUX FUEL and the MASTER CAUTION lights, but does not correct the no .ow condition.

FAIL Open in vent sensor line.
4.10.4 External Extended Range Fuel Quantity In-dicating System. The AUX FUEL QTY POUNDS digital readout (Figure 4-18) displays the amount of fuel remaining. Fuel type is preset by switches in the AUXIL-IARY FUEL MANAGEMENT panel. Preset can only be done when the helicopter weight is on the wheels. When measuring quantity, the readout is used in conjunction with the rotary selector switch to select tank pair subtotal, or TOTAL remaining in all tanks. Fuel used is sensed from a common .ow transmitter within the fuel line to the main tanks. This amount is subtracted from the preset fuel quan-tity input and is displayed on the digital readout as pounds remaining. A DEGRADED light will go on, when a com-plete failure has occurred in the microprocessor, or an error condition is detected by the microprocessor, or when the temperature sensor has failed. Power for the fuel quantity subsystem is provided from the No. 2 ac primary bus through a circuit breaker marked AUX FUEL QTY,onthe mission readiness circuit breaker panel.
4.10.5 Auxiliary Fuel Management Control Panel Test.
1.  
TEST button -Press. Digits should display 8’s and DEGRADED and VENT SENSOR (FAIL and OVFL) lights should illuminate.

2.  
TEST button -Release. Digits should display 8’s in sequence from left to right three times; 5 seconds later, display GOOD or EO failure code; 3 seconds later, display type fuel density, then fuel TOTAL.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:UH-60Q 直升机技术手册 直升机操作手册 1(142)