Lavatory Fluorescent Lights
___________________________
 A.  The lavatory lights are two fluorescent lights mounted at the ceiling.
 115 volts ac is applied through circuit breakers on the P414 panel.Lavatory Lights Ballast
_______________________
 A.  The lavatory fluorescent lamp ballast is a solid state device, capable of beint dimmed. 115 volts ac is applied continously to the ballast. Ballast operation is controlled by the electrical state of a pair of control line inputs.
 B.  When DIM/BRT continuity is maintained through the RETURN TO SEAT relay and the GROUND HANDLING BUS relay, the lights will remain dim.
 C.  When this line is opened by either of the relays, the lights will remain
 bright, regardless of the door locked switch position.Lavatory Door Lock
__________________
 A.  The lavatory door limit swich is located in the lavatory door frame behind the door bolt striker plate.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-26-00
 ALL  ú ú 01A Page 1 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 B.  The limit switch is normally operated by closing the lavatory door and setting the door lock bolt to LOCK position. One set of contacts operates the DIM/BRT circuit of the ballast. The other set operates the FLT DK LAV OCC light.
 C.  The limit switch may be operated manually when the door is open by depressing the striker plate.
 6.  Lavatory Information Sign Switch
________________________________
 A.  General
 (1)  The LOCK DOOR and RETURN TO SEAT signs are symbolic displays on a graphic strip. The strip is ulluminated from the back by a light assembly of two rows of light emitting diodes (LEDs).
 B.  The LOCK DOOR sign is installed behind the graphic retainer at the bottom of the dispenser cabinet.
 C.  The RETURN TO SEAT sign is installed behind the graphic strip retainer at the bottom of the lavatory mirror.
 7.  Lavatory Call Switches
______________________
 A.  The call pushbutton switches near the counter sink will become
 illuminated with a symbolic display when actuated.

 B.  The lavatory call light and reset switch above the door resets the call when actuated.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-26-00
 ALL  ú ú 01A Page 2 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 FAULT ISOLATION/MAINT MANUAL
LAVATORY MASTER CALL LIGHTS

 * SEE THE SSM OR WDM FOR THE EQUIPMENT NUMBER, QUANTITY AND LOCATION OF EACH COMPONENT IN THE LIGHTING CIRCUIT.
Lavatory Master Call Lights - Component Index
Figure 101

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-26-00
 ALL  ú ú 01 Page 101 ú Oct 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
E56002
A
747-400 FAULT ISOLATION/MAINT MANUAL

LAVATORY CALL SWITCH


Lavatory Master Call Lights
Figure 102

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-26-00
 ALL  ú ú 01 Page 102 ú Oct 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
E56003
A
747-400 MAINTENANCE MANUAL
 LAVATORY LIGHTS - ADJUSTMENT/TEST
_________________________________
 1.  General_______
 A.  This procedure contains a task to do an operational test of the lights in the lavatory.
 TASK 33-26-00-715-001
 2.  Lavatory Lights Operational Test________________________________
 A.  References
 (1)  
 
中国航空网 www.aero.cn