1) Aft Center Miscellaneous Circuit Breaker Panel, P84 a) LOGO LIGHTS - LEFT b) LOGO LIGHTS - RIGHT
(b)
On the pilot's overhead panel, P5,
push the LOGO switch to the ON position.
(c)
Make sure that the logo lights connected to the transformer come on.
(d)
Push the LOGO switch to the OFF position.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
33-45-00
ALL ú ú 02 Page 209 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
S 412-054
(8)
Close the access panel on the lower surface of the horizontal stabilizer.
S 942-100
(9)
Disconnect the attach lanyard from the horizontal stabilizer.
S 862-101
(10)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:
(a) Overhead Circuit Breaker Panel, P7 1) 7E07, STAB TRIM S/O LEFT 2) 7E20, STAB TRIM S/O RIGHT
S 862-102
(11)
On the pilot's control stand panel, P8, set the STAB TRIM 2 switch and the STAB TRIM 3 switch to the ON position.
S 862-103
(12)
Remove electrical power if it is not necessary for other tasks (AMM 24-22-00/201).
TASK 33-45-00-712-080
5. Logo Lights - Operational Test
______________________________
A. References
(1) AMM 24-22-00/201, Manual Control
B. Access
(1) Location Zones
222 Control Cabin, Right
C. Procedure
S 862-081
(1)
Supply electrical power (AMM 24-22-00/201).
S 712-082
(2)
Do these steps to test the logo lights:
(a)
On the pilot's overhead panel, P5, push the LOGO switch to the ON position.
(b)
Make sure that all four logo lights come on.
(c)
Push the LOGO switch to the OFF position.
(d)
Make sure that all four logo lights go off.
S 862-083
(3) Remove electrical power if it is not necessary for other tasks (AMM 24-22-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
33-45-00
ALL ú ú 01 Page 210 ú Jun 10/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
TASK 33-45-00-822-058
6. Logo Light - Light Beam Adjustment (Fig. 201)__________________________________
A. Equipment
(1)
24MIT65B00002 - Attach Lanyard - Saftety Harness Wing/Horizontal Stabilizer
(2)
Full Body Harness
D.B. Industries
3965 Pepin Avenue
Redwing, MN 55066-1837
Phone: (612) 388-8282
(3)
Sealing Gun
(4)
Spatula
B. References
(1)
AMM 24-22-00/201, Manual Control
(2)
AMM 51-31-01/201, Seals and Sealing
C. Access
(1) Location Zone 222 Control Cabin, Right 334 Horizontal Stabilizer Rear Spar To Trailing Edge, Left 344 Horizontal Stabilizer Rear Spar To Trailing Edge, Right
D. Procedure
(1) S 862-104Supply electrical power (AMM 24-22-00/201).
(2) S 862-105On the pilot's control stand panel, P8, set the STAB TRIM 2 switch and the STAB TRIM 3 switch to the CUTOUT position.
(3) S 862-106Open these circuit breakers and attach DO-NOT-CLOSE tags: (a) Overhead Circuit Breaker Panel, P7 1) 7E07, STAB TRIM S/O LEFT 2) 7E20, STAB TRIM S/O RIGHT
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
33-45-00
ALL ú ú 01 Page 211 ú Jun 18/01