MAINTENANCE MANUAL

 C. Access
 (1)  Location Zone
 200 Upper Half of Fuselage

 D. Procedure
 S 392-021
 (1)  
Clean the fuselage to prepare it for the aerodynamic smoother you will apply around the light (AMM 51-31-01/201).

 S 142-022

 (2)
If it is necessary, use sandpaper to clean the base of the light.

 S 422-023

 (3)  
Install the light assembly with its screws.

 S 432-024

 (4)  
Connect the electrical wires.

 S 432-029

 (5)  
Install the lens with the screws.

 S 392-030

 (6)  
With the sealing compound, apply an aerodynamic smoother around the base of the light (AMM 51-31-01/201).

 S 862-035

 (7)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:


 (a)  On the overhead circuit breaker panel, P7:
 1) 7G14, CHG EMER LT

 E. Light Test
 S 712-008
 CAUTION: KEEP THE OPERATION OF THE EMERGENCY LIGHTS TO LESS THAN A ONE
_______ MINUTE TIME. THE BATTERIES THAT SUPPLY THE ELECTRICAL POWER TO THE EMERGENCY LIGHTS WILL ONLY OPERATE FOR 15 MINUTES WHEN FULLY CHARGED.
 (1)  On the pilot's overhead panel, P5,
 set the EMER LIGHTS switch to the ON position.

 (a)  Make sure the light comes on correctly.
 S 862-009
 (2)  Set the EMER LIGHTS switch to the OFF position.
 (a)  Make sure the emergency lights go off.