 3) 6L2 FLT DECK LIGHT DOME


 (b)  
P414 Power Distribution Center - Left
 1) 414L1 NOSE GEAR TAXI LIGHT
 2) 414L2 LANDING LT RIGHT INBD
 3) 414L3 LANDING LT LEFT INBD
 4) 414L20 LIGHT RUNWAY TURNOFF LEFT & CONT
 5) 414L21 LIGHT RUNWAY TURNOFF RIGHT


 (c)  
P415 Power Distribution Center - Right
 1) 415L31 LANDING LT LEFT OUTBD
 2) 415L32 LANDING LT RIGHT OUTBD

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-11-04
 ALL  ú ú 02 Page 408 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 864-078
 (8)  RIGHT CONTROL MODULE (M7262); Remove the DO-NOT-CLOSE tags and close these circuit breakers:
 (a)  
P6 Main Power Distribution Panel
 1) 6F19 PILOTS MISC IND LTS 1
 2) 6F20 PILOTS MISC IND LTS 2
 3) 6F26 F/O IND LTS
 4) 6F27 F/O IND & DGTL DSPL
 5) 6L4 CAPT IND LTS
 6) 6L5 LTS IND & DGTL DSPL - CAPT
 7) 6L28 L WING NAV LTS & CONT
 8) 6L29 R WING NAV LTS
 9) 6L30 TAIL NAV LTS
 10) 6L31 RED ANTI-COLLISION LIGHTS
 11) 6L32 WHITE ANTI-COLLISION LIGHTS
 12) 6L33 WING ILLUMINATION LIGHTS


 (b)  
P84 Aft Center Miscellaneous Circuit Breaker Panel
 1) LOGO LIGHTS - RIGHT
 2) LOGO LIGHTS - LEFT

 

 S 714-072
 (9)  LEFT (M7261) OR CENTER (M7263) CONTROL MODULE; Do a test of the replaced control:
 (a)  
Supply electrical power (Ref 24-22-00/201).

 (b)  
Turn the knob on the replaced control full clockwise.

 (c)  
Make sure the light intensity changes smoothly.

 (d)  
Remove the electrical power if it is not necessary
 (Ref 24-22-00/201).

 

 S 714-077
 (10) RIGHT CONTROL MODULE (M7262); Do these steps to test the replaced module:
 (a)  
Supply electrical power (AMM 24-22-00/201).

 (b)  
Set and hold the IND LTS switch, on the control module, in the TEST position.

 (c)  
Make sure the indicator lights come on.


 NOTE: Refer to SSM 33-12-01, to identify which indicator
____
 lights will come on.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-11-04
 ALL  ú ú 01 Page 409 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (d)  After approximately 10 seconds, make sure the indicator lights become dim.
 (e) (f)  Set the IND LTS switch to the BRT position.Make sure the indicator lights go off.
 NOTE:____ It is possible that some of the indicator lights will stay on. If this occurs, make sure that it is the correct operation of each indicator light that stayed on (SSM 33-12-01).
 (g)  Remove electrical power if it is not necessary (AMM 24-22-00/201).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-11-04
 ALL  ú ú 01 Page 410 ú Jun 10/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 PANEL LIGHT DIMMER - REMOVAL/INSTALLATION
_________________________________________
 1.  General
_______
 A.  This procedure has these tasks:
 (1)  
The removal and installation of dimmers installed in the P7 panel.

 (2)  
The removal and installation of dimmers installed in the P9 aisle control stand.


 B.  Twelve light dimmers supply adjustable voltages for the
 instrument lights.

 (1)  
Eight dimmers are installed in the P9 aisle control stand behind the Control Display Units (CDU).
 
中国航空网 www.aero.cn