 (1)  Location Zone 200 Forward Upper Deck - Passenger Compartment.
 C. Procedure
 S 864-002
 WARNING: DO NOT TOUCH THE POWER SUPPLY FOR 10 MINUTES AFTER YOU REMOVE
_______ THE POWER. AN ELECTRICAL SHOCK FROM THE HIGH VOLTAGE IN THE POWER SUPPLY CAN CAUSE INJURY TO PERSONS.
 (1)  Open this circuit breaker and attach a DO-NO-CLOSE tag:
 (a)  
P6 Main Power Distribution Panel
 1) 6L31 ANTI COLL LTS RED


 (b)  
Find the ceiling panel at station 568 (the fifth ceiling panel forward of the midrange lowered ceiling).


 NOTE: Some airplanes have a panel installed in the
____ ceiling panel to get access to the power supply.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-44-09
 ALL  ú ú 01 Page 401 ú Oct 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

CABLE TO THE UPPER BEACON MOUNTING BOLT LIGHT (4 LOCATIONS)

UPPER BEACON LIGHT POWER SUPPLY

Upper and Lower Beacon Light Power Supply Installation
Figure 401 (Sheet 1)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-44-09
 ALL  ú ú 01 Page 402 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

AIR CONDITIONING BAY  LOWER BEACON 
ACCESS DOORS  LIGHT POWER 
SUPPLY 
SEE  B 
ACCESS 
PANEL 

FWD
MOUNTING BOLT
POWER (4 LOCATIONS)
SUPPLY
ELECTRICAL CONNECTORS
LOWER BEACON LIGHT
LOWER BEACON LIGHT POWER SUPPLY
B
Upper and Lower Beacon Light Power Supply Installation Figure 401 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-44-09
 ALL  ú ú 01 Page 403 ú Feb 10/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (c)  
AIRPLANES WITH AN ACCESS PANEL; Open the access panel in the ceiling panel.

 (d)  
AIRPLANES WITHOUT AN ACCESS PANEL; Remove the ceiling panel (AMM 25-22-03/401).


 S 004-032
 (2)  Do these steps to remove the power supply:
 (a)  
Disconnect the electrical connector.

 (b)  
Remove the mounting bolts.

 (c)  
Remove the power supply.


 TASK 33-44-09-404-006
 3.  Installation (Upper Beacon Light Power Supply) (Fig. 401)______________________________________________
 A. References
 (1)  
AMM 24-22-00/201, Manual Control

 (2)  
AMM 25-22-03/401, Upper Deck Ceiling Panel

 (3)  
AIPC 33-44-09 Fig. 2

 (4)  
SSM 33-44-01


 B. Access
 (1)  Location Zone 200 Forward Upper Deck, Passenger Compartment
 C. Procedure
 S 404-033
 (1)  Do these steps to install the power supply:
 (a)  
Put the power supply in its position.

 (b)  
Install the mounting bolts.

 (c)  
Connect the electrical connector.


 S 414-009
 (2) Close and latch the access panel (AMM 25-22-03/401).
 D. Installation Test
 S 864-010
 (1)  
Supply electrical power (AMM 24-22-00/201).

 S 864-011

 (2)  
Remove the DO-NOT-CLOSE tag and close this circuit breaker:


 (a)  P6 Main Power Distribution Panel 1) 6L31 ANTI COLL LTS RED
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 33-44-09
 ALL  ú ú 01 Page 404 ú Oct 15/98
 