• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-29 14:34来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 - HJ13 harness

 - ECU (4000KS)

 

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 73-21-50-000-029 Removal of the CJ13 Harness AMM 73-21-50-000-046 Removal of the HJ13 Harness AMM 73-21-50-210-001 Visual Inspection of the Wiring Harness AMM 73-21-50-400-029 Installation of the CJ13 Harness AMM 73-21-50-400-046 Installation of the HJ13 Harness AMM 73-21-60-000-001 Removal of the Electronic Control Unit (ECU) AMM 73-21-60-400-001 Installation of the Electronic Control Unit (ECU) AMM 73-29-00-710-040 Operational Test of the FADEC on the Ground (with
 Engine non Motoring) AMM 77-23-10-000-002 Removal of the Compressor Discharge Temperature (T3) Sensor AMM 77-23-10-400-002 Installation of the Compressor Discharge Temperature (T3) Sensor
 3. Fault Confirmation
__________________
 A. Do the operational test of the FADEC 1A and 1B on the ground (with engine non motoring) (Ref. AMM TASK 73-29-00-710-040).
 4. Fault Isolation
_______________

 A. The failure message is generated if channel B sensor signal is invalid or out of range.
R NOTE : If T3 sensor Part Number is 1348M21P01, P04 or P05, replace T3
____ R sensor (Ref. AMM TASK 77-23-10-000-002) and (Ref. AMM TASK 77-23-10-400-002).
R (1) If the failure messages T3 SNSR, J13, ECU + T3 SNSR, J13, ECU are not R confirmed:
 - no maintenance action is required.
 F 『 EEFF : ALL E ∞∞77-20-00∞∞∞∞∞∞∞∞∞∞Page 207
 E E Aug 01/99 E E ECES
ER (2) If the failure messages T3 SNSR, J13, ECU + T3 SNSR, J13, ECU are not R confirmed, but are repetitive:

 F  『
 E  C F M  E
 E  E
 E  56  E
 E  E 

 

 - visually examine the T3 thermocouple receptacle and the CJ13 harness connector for damaged pins and contamination (Ref. AMM TASK 73-21-50-210-001).
R (a) If harness connector or T3 thermocouple receptacle is damaged:
 - repair or replace as required.
 (b) If no damage is found:
 - visually examine the ECU (4000KS) receptacle and the HJ13 harness connector for damaged pins and contamination (Ref. AMM TASK 73-21-50-210-001).
R 1_If harness connector or ECU receptacle is damaged:
 - repair or replace as required.
 2 If no damage is found:
_

 - replace the T3 thermocouple (Ref. AMM TASK 77-23-10-000-002) and (Ref. AMM TASK 77-23-10-400-002).
R (c) If the fault continues during the subsequent flights:
 - replace the CJ13 harness (Ref. AMM TASK 73-21-50-000-029) and (Ref. AMM TASK 73-21-50-400-029).
R (d) If the fault continues during the subsequent flights:
 - replace the HJ13 harness (Ref. AMM TASK 73-21-50-000-046) and (Ref. AMM TASK 73-21-50-400-046).
R (e) If the fault continues during the subsequent flights:
 - replace the ECU (4000KS) (Ref. AMM TASK 73-21-60-000-001) and (Ref. AMM TASK 73-21-60-400-001).
R (3) If the failure messages T3 SNSR, J13, ECU + T3 SNSR, J13, ECU are R confirmed: R - disconnect the two CJ13 connectors from the T3 thermocouple R - visually examine the T3 thermocouple receptacle and the CJ13 R harness connectors for damaged pins and contamination (Ref. AMM
 TASK 73-21-50-210-001).
R (a) If harness connectors or T3 thermocouple receptacle are damaged:
 - repair or replace as required.
 (b) If no damage is found: R - do a resistance check of the two T3 thermocouple connectors R between:
 . pins A and B (0.5 to 10 ohms) . pin A and the ground (> 10 megohms).
 1 If the resistance values of one of the two T3 thermocouple
_ connectors are out of specified limits:
 F 『
 ∞∞77-20-00∞∞∞∞∞∞∞∞∞∞Page 208

EEFF :  ALL  E 
E  E  Aug 01/99
 E  E
 ECES  E


 F  『
 E  C F M  E
 E  E
 E  56  E
 E  E

 

 - replace the T3 thermocouple (Ref. AMM TASK 77-23-10-000-002)
 and (Ref. AMM TASK 77-23-10-400-002).
 2_ If the resistance values are in the specified limits:
 - reconnect the CJ13 harness to the T3 thermocouple
 - disconnect the HJ13 harness from the ECU
 - visually examine the ECU (4000KS) receptacle and the HJ13
 harness connector for damaged pins and contamination (Ref.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 发动机指示(167)