(3) Remove the ground support and maintenance equipment, the special and
 standard tools and all other items. 
R
 1EFF : ALL 1 32-11-00Page 607 1 1 Nov 01/04 1 1 1CES 1 TASK 32-11-00-220-003
 Detailed Dimensional Check of the MLG Lockstay Assembly
 WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
 START A TASK ON OR NEAR:
 -
THE FLIGHT CONTROLS
 -
THE FLIGHT CONTROL SURFACES
 -
THE LANDING GEAR AND THE RELATED DOORS
 -COMPONENTS THAT MOVE.
 WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
 GEAR.
 1. Reason for the Job
__________________
 A dimensional check of the length of the MLG lockstay actuator after replacement of:
 -
a lockstay actuator
 -
a side-stay assembly.
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific non metallic scraper
 No specific safety barriers
 No specific warning notice
 No specific access platform 2.5 m (8 ft. 2 in.)
R No specific  Torque Wrench : range 0.00 to 1.20 m.daN 
R (0.00 to 9.00 lbf.ft) 460006437 1 TOOL-HOLDING 460007262 1 CHECKING GAUGE
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 09-016  USA MIL-PRF-81733D TYPE II CLASS B
 CORROSION INHIBITING FILLET CONSISTENCY
 (Ref. 20-31-00)
1EFF : ALL 1 32-11-00Page 608 1 1 May 01/05 1 1 1CES 1
 C. Expendable Parts
 -------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION  |IPC-CSN
 -------------------------------------------------------------------------------
8 cotter pin  32-11-17 01 -030 
R  8 cotter pin 32-11-17 01A-030 8 cotter pin 32-11-17 01B-030
 D. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
07-11-00-581-001 Lifting for Aircraft Maintenance Operations 07-11-00-586-002 Lowering of the Aircraft for Maintenance Operations 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
 the Ground Connector 32-00-00-481-001 Installation of the Safety Devices on the Landing Gears 32-11-16-400-001 Installation of the MLG Side-Stay Assembly 2505GM,
 2506GM 32-11-21-000-001 Removal of the MLG Lockstay Actuating Cylinder 32-11-21-400-001 Installation of the MLG Lockstay Actuating Cylinder 32-12-00-010-001 Open the Main Gear Doors for Access 32-12-00-410-001 Close the Main Gear Doors after Access CMM 321121 (for corrective action) 32-11-00-991-026 Fig. 601 32-11-00-991-024 Fig. 602
 3. Job Set-up
__________
 Subtask 32-11-00-941-062
 A. Safety Precautions
 (1)
 Put the safety barriers in position.
 (2)
 On the panel 400VU:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架1(101)