R (3) Do an Inspection of the Insulation Mats
R R R CAUTION : MAKE SURE THAT THE INSULATION MATS ARE NOT DAMAGED. DAMAGED_______ INSULATION MATS CAN CAUSE WATER TO GO INTO THE TAPPING UNIT. WATER CAN CAUSE DAMAGE TO THE TAPPING UNIT.
R R (a) Make sure that the insulation mats adjacent to the tapping unit are clean and in the correct condition.
4. Procedure_________
**ON A/C 051-099, 201-210,
(Ref. Fig. 401/TASK 23-36-44-991-001)
**ON A/C 106-149, 211-299,
(Ref. Fig. 401A/TASK 23-36-44-991-001-B)
**ON A/C 151-199,
(Ref. Fig. 401B/TASK 23-36-44-991-001-A)
**ON A/C 301-399,
(Ref. Fig. 401C/TASK 23-36-44-991-001-C)
**ON A/C 051-099, 201-210,
Subtask 23-36-44-420-050
R A. Installation of the Tapping Unit (TU)
R R R (1) On the top of the tapping unit (4), put each micro switch to its required position.
R R NOTE : At the end of the tapping unit lines the tapping unit must end____ with a termination plug. If a related tapping unit is installed, connect the termination plug to the tapping unit connector J3.
R (2) Carefully install the tapping unit (4) and lock the nylatches (1).
(3) Remove the blanking caps from the electrical connectors (2).
(4) Make sure that the electrical connectors are clean and in the correct
condition.
R (5) Connect the Electrical Connectors
R CAUTION : MAKE SURE THAT THE CABLE CONNECTIONS OF THE TAPPING UNIT_______
R ARE INSTALLED CORRECTLY AND HAVE A LOW-POINT LOOP. IF YOU
R DO NOT HAVE A LOW-POINT LOOP IN THE CABLES, WATER CAN GO
R INTO THE TAPPING UNIT. WATER CAN CAUSE DAMAGE TO THE
R TAPPING UNIT.
R NOTE : You can find the instruction to install cables with a____
R low-point loop in the ESPM 20-33-11 fig. 018.
R (a) Connect the electrical connectors (2) to the tapping unit (4) and
R safety with the spring latches (3).
**ON A/C 106-149, 151-199, 211-299, 301-399,
Subtask 23-36-44-420-050-A
R A. Installation of the Tapping Unit (TU)
(1) Carefully install the tapping unit (4) and lock the nylatches (1).
R NOTE : At the end of the tapping unit lines the tapping unit must end____
R with a termination plug. If a related tapping unit is
installed, connect the termination plug to the tapping unit
connector J3.
(2) Remove the blanking caps from the electrical connectors (2).
(3) Make sure that the electrical connectors are clean and in the correct
condition.
R (4) Connect the Electrical Connectors
R CAUTION : MAKE SURE THAT THE CABLE CONNECTIONS OF THE TAPPING UNIT_______
R ARE INSTALLED CORRECTLY AND HAVE A LOW-POINT LOOP. IF YOU
R DO NOT HAVE A LOW-POINT LOOP IN THE CABLES, WATER CAN GO
R INTO THE TAPPING UNIT. WATER CAN CAUSE DAMAGE TO THE
R TAPPING UNIT.
R NOTE : You can find the instruction to install cables with a____
R low-point loop in the ESPM 20-33-11 fig. 018.
R 1EFF : 051-099, 106-149, 151-199, 201-299, 1 23-36-44Page 413 1301-399, 1Aug 01/05 1 1 1CES 1R (a) Connect the electrical connectors (2) to the tapping unit (4) and R safety with the spring latches (3). R
**ON A/C 051-099,
Subtask 23-36-44-865-052-C
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
------------------------------------------------------------------------------
2000VU PES/VIDEO/CTL 21MH 01 C
2000VU PES/VIDEO/CABIN/LH 22MH 02 C
2000VU PES/VIDEO/CABIN/RH 23MH 03 C
**ON A/C 106-149, 211-299,
Subtask 23-36-44-865-052-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
------------------------------------------------------------------------------
PANEL SERVICE IDENT. LOCATION
------------------------------------------------------------------------------
2000VU PES/VIDEO/CONTROL/MAIN 20MH 01 C
2000VU PES/VIDEO/CONTROL/VCC 21MH 02 C
2000VU PES/VIDEO/CABIN/LH 22MH 03 C
2000VU PES/VIDEO/CABIN/RH 24MH 04 C
**ON A/C 151-199, 201-210,
Subtask 23-36-44-865-052
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):