On the SCU 11MH:
-
the integral light of the MASTER POWER pushbutton switch comes on,
-all LED come on while the SCU 11MH does the self test of the system, 
-
the green LED SYSTEM TEST/PASS comes on when the self test is complete.
On the PES video SCU 11MH, on the monitor:
-
the PROGRAMMABLE PSCU page comes into view.
 1EFF : 301-399, 1 23-36-00Page 321 1 1 Nov 01/04 1 1 1CES 1
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------R NOTE : Wait for a minimum of 3 minutes after the SCU power-on, then continue
____ On the SCU 11MH, on the monitor: 
R  with the procedure.  
R  3. On the SCU 11MH, on the key pad:  
R  - push CLEAR the membrane switch.  
R  
R  4. On the SCU 11MH, MODE SELECT  
R  area:  
R  - push and hold the menbrane  
R  switch for 5 seconds.  
R  5. On the SCU 11MH, on the key pad:  
R  - push four times the '9'  
R  membrane switch.  
R  - push ENTER the membrane switch.  
R  
R  6. On the SCU 11MH, on the key pad:  
R  - push the up or down arrow  
R  membrane switch to move the  
R  cursor to the item PC CARD/RSD  
R  - push the ENTER membrane switch.  
R  
R  7. On the SCU 11MH, on the key pad:  
R  - push the up or down arrow  
R  membrane switch to move the  
R  cursor to the item PC CARD,  
R  - push the ENTER membrane switch.  
R  
R  8. On the SCU 11MH:  
R  - push the up or down arrow  
R  membrane switch to move the
-
the AUTO MODE selection page comes into view.
On the SCU 11MH, on the monitor:
-
the MAINTENANCE MODE page comes into view.
On the SCU 11MH, on the monitor:
-
the MAINTENANCE MODE selection page comes into view.
On the SCU 11MH, on the monitor:
-
the PC CARD/RSD selection page comes into view.
On the SCU 11MH, on the monitor:
-
the PC CARD selection page comes into view.
On the SCU 11MH, on the monitor: 
1EFF : 301-399, 1 23-36-00Page 322 1 1 Nov 01/04 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
cursor to the item DOWNLOAD PC CARD
 -push the ENTER membrane switch. 
9. On the SCU 11MH, on the key pad: 
-insert the PC card in the slot of the SCU,
 -
push the up or down arrow membrane switch to move the cursor to the item FLIGHT INFORMATION,
 -
push the ENTER membrane switch,
10. On the SCU 11MH: 
-push the ENTER membrane switch. 
11. On the SCU 11MH: 
-push the pushbutton switch MASTER POWER,
-
the DOWNLOAD PC CARD selection page comes into view.
On the SCU 11MH, on the monitor:
-
the DOWNLOAD FLIGHT INFO page comes into view.
On the SCU 11MH, on the monitor:
- on the DOWNLOAD FLIGHT INFO page thefollowing messages come into the view: WARNING: DO NOT INTERRUPT THIS PROCESS. DOING SO WILL RENDER AUTO MODE INOPERAABLE 10% COMPLETED
 When the download process is completed:
 - on the DOWNLOAD FLIGHT INFO page the following messages come into the view: DOWNLOAD WAS SUCCESSFUL
 PLEASE
 CYCLE POWER
On the SCU 11MH:
 1EFF : 301-399, 1 23-36-00Page 323 1 1 May 01/05R 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-wait for a minimum of 5
 seconds after the SCU
 power-off,
 12. In the VCC 10MH:  In the VCC 10MH:
 -push the VCC MASTER POWER  - the integral light of the VCC MASTER
 SWITCH pushbutton switch.  POWER SWITCH pushbutton switch goes off.
R **ON A/C 106-149, 211-299, 301-399,
 5. Close-up
________
 Subtask 23-36-00-410-055
 A. Close Access
 (1) Close the applicable overhead stowage compartment(s).
 Subtask 23-36-00-862-052
 B. De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002).
R 1EFF : 106-149, 211-299, 301-399, 1 23-36-00Page 324 1 1 May 01/05 1 1 1CES 1 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM Communications 通讯2(55)