(2)
Make sure that the access door 824 is open.
1EFF : ALL 1 23-33-39Page 404 1 1 Feb 01/03 1 1 1CES 1 Subtask 23-33-39-865-051
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
123VU BUS 2/210XP/SPLY 7XN2 AF02
4. Procedure
_________
(Ref. Fig. 401/TASK 23-33-39-991-001) Subtask 23-33-39-420-050
A. Installation of the SERVER - IFE
(1)
Clean the component interface and/or the adjacent area.
(2)
Do an inspection of the component interface and/or the adjacent area.
(3)
Remove the blanking caps from the electrical connectors (1).
(4)
Make sure that the electrical connectors (1) are clean and in the correct condition.
(5)
Install the SERVER - IFE (5) in its rack (2).
(6)
Push the SERVER - IFE (5) on its rack (2) to connect the electrical connectors (1).
(7) Engage the nuts (3) on the lugs (4) and tighten. Subtask 23-33-39-865-052
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 7XN2
Subtask 23-33-39-740-050
C. Do the BITE test of the IFE CENTER (Ref. TASK 23-33-00-740-002).
1EFF : ALL 1 23-33-39Page 405 1 1 Feb 01/03 1 1 1CES 1
5. Close-up
________ Subtask 23-33-39-410-050
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access door 824 (Ref. TASK 52-41-00-410-002).
(3)
Remove the access platform(s).
1EFF : ALL 1 23-33-39Page 406 1 1 Feb 01/03 1 1 1CES 1 SEAT ELECTRONIC BOX (SEB) - REMOVAL/INSTALLATION
________________________________________________
TASK 23-33-46-000-001
Removal of the Seat Electronic Box (SEB)
WARNING : ISOLATE THE ELECTRICAL CIRCUITS FROM THE RELATED EQUIPMENT AND THE
_______
ENVIRONMENT.
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R **ON A/C 051-099, 201-210,
23-33-46-991-001 Fig. 401 R **ON A/C 106-149, 211-299, 301-399,
23-33-46-991-001-A Fig. 401A
R 1EFF : 051-099, 106-149, 201-299, 301-399, 1 23-33-46Page 401 1 1 May 01/05 1 1 1CES 1
R **ON A/C 051-099, 106-149, 201-299, 301-399,
3. Job Set-up__________
R **ON A/C 051-099, 201-210,
(Ref. Fig. 401/TASK 23-33-46-991-001)
R **ON A/C 106-149, 211-299, 301-399,
(Ref. Fig. 401A/TASK 23-33-46-991-001-A)
R **ON A/C 051-099,
R Subtask 23-33-46-865-050-C
R A. Open, safety and tag this(these) circuit breaker(s):
R R R R -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU PES/MUSIC/CTL 21MK D01
R **ON A/C 106-149, 211-299,
Subtask 23-33-46-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):