ENG START selector...............................................................................................................NORM
Applicable to: ALL
L/G
L/G lever.........................................................................................................Check DOWN position
Applicable to: ALL
WIPERS
WIPERS..................................................................................................................................... OFF
Applicable to: ALL
ELEC
 If the aircraft has not been electrically supplied for 6 h or more, perform the following
check.
BAT 1 pb-sw, BAT 2 pb-sw and APU BAT pb-sw.................................................. CHECK OFF
BAT 1 and 2 and APU BAT VOLTAGE..................................................CHECK ABOVE 25.5 V
Battery voltage above 25.5 V ensures a charge above 50 %. After the check, the selector
should remain on APU position to avoid discharge of BAT 1 or 2.
A330/A340 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
NORMAL PROCEDURES
STANDARD OPERATING PROCEDURES
- PRELIMINARY COCKPIT PREPARATION
A330/A340 FLEET PRO-NOR-SOP-04 P 2/10
FCOM 19 AUG 10
 If battery voltage is below 25.5 V:
a charging cycle of about 20 min is required.
BAT 1 pb-sw, BAT 2 pb-sw and APU BAT pb-sw.......................................................AUTO
EXT PWR......................................................................................................................... ON
Check on ELEC DC SD page, battery contactors closed and batteries charging.
 after 20 min:
BAT 1 pb-sw, BAT 2 pb-sw and APU BAT pb-sw......................................................... OFF
BAT 1 and 2 and APU BAT VOLTAGE........................................... CHECK ABOVE 25.5 V
After the check, the selector should remain on APU position.
 If battery voltage is above 25.5 V:
BAT 1 pb-sw, BAT 2 pb-sw and APU BAT pb-sw.......................................................AUTO
Note: The ground horn will be triggered, associated with the ventilation EXTRACT
FAULT illumination and ECAM warning after 5 min when the aircraft is supplied
with batteries only.
 If the aircraft has been electrically supplied during the last 6 h
BAT 1 pb-sw, BAT 2 pb-sw and APU BAT pb-sw.............................................................AUTO
Note: In case of APU start on battery only, perform the following check:
BAT 1 pb-sw, BAT 2 pb-sw and APU BAT pb-sw.............................................. AUTO
BAT 1 and 2 and APU BAT.....................................................CHECK ABOVE 23.5 V
If one battery voltage is lower than 23.5 V, there is a risk of aborted APU start.
A charging cycle of the battery is required.
EXT PWR (if AVAIL is on)............................................................................................................ON
AVAIL goes out.
Note: 1. When only one electrical power is available it is recommended to connect EXT PWR A
since:
EXT PWR B does not permit GND/FLT buses ‐ to be supplied directly without
energizing the total aircraft network.
‐ EXT PWR B cannot be used simultaneously with APU GEN.
2. If AVAIL does not come on (EXT PWR connected) or ON/AVAIL go out during
EXT PWR operation, the GPCU protection has tripped. Reset using the EXT PWR.
A330/A340 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
NORMAL PROCEDURES
STANDARD OPERATING PROCEDURES
- PRELIMINARY COCKPIT PREPARATION
A330/A340 FLEET PRO-NOR-SOP-04 P 3/10
FCOM 19 AUG 10
Applicable to: ALL
HYD
WARNING Do not pressurize hydraulic systems without clearance from ground crew.
APU FIRE TEST/START
Applicable to: ALL
APU FIRE
APU FIRE pb-sw...................................................................................................IN and GUARDED
AGENT light ............................................................................................................................... OUT
If the APU is already running ensure that the following check has already been completed.
If not, perform it.
APU FIRE TEST pb .............................................................................................................. PRESS
Check:
‐ APU FIRE warning on ECAM + CRC + MASTER WARN light
‐ APU FIRE pb-sw lighted red
‐ APU SQUIB light and APU DISCH light on.
Applicable to:
APU START
APU MASTER SW pb-sw ............................................................................................................ON
APU ON light comes on.
APU SD page appears on ECAM.
Note: If batteries only are supplying, press the APU pb on the ECAM control panel during the
start sequence (to permit the ECAM upper display to display the APU SD page).
 