EMC EMI probe set sniffer 100kHz to 3GHz
High performance sniffer-set for the SPECTRAN NF-50xx and HF-60xx Analyzer-Series
Data sheet
References / examples of proof:
EADS Deutschland GmbH, Unterschleissheim
EnBW Kernkraftwerk GmbH, Neckarwestheim
Universität Erlangen, Erlangen
Saarschmiede GmbH, Völklingen
w
w
w
w
1
Made in Germany
1 x 60mm magnetic field probe
1 x 30mm magnetic field probe
1 x 10mm magnetic field probe
1 x isotropic E-field probe
1 x directional E-field probe
Pre-amplifier with power supply (only PBS2)
Transport case with paddings
Exhaustive manual (English)
Included with delivery:
w
w
w
w
w
w
w
w
Rev 1.2
12.03.2010
2
Specifications:
H field shielding: 30dB
Maximum resonance frequency: >3GHz
Connector: 50 Ohms BNC socket (f)
Warranty: 10 years
Isotropic E-field sniffer:
w
w
w
E-field shielding: 30dB
Maximum resonance frequency: >3GHz
Connector: 50 Ohms BNC socket (f)
Warranty: 10 years
Directional E-field probe:
w
w
w
E Field shielding: 41dB
Maximum resonance frequency: 790MHz
Connector: 50 Ohms BNC socket (f)
Warranty: 10 years
10mm magnetic field probe:
w
w
w
E-field shielding: 29dB
Maximum resonance frequency: 1.5GHz
Connector: 50 Ohms BNC socket (f)
Warranty: 10 years
30mm magnetic field sniffer:
w
w
w
E-field shielding: 11dB
Maximum resonance frequency: 2.3GHz
Connector: 50 Ohms BNC socket (f)
Warranty: 10 years
60mm magnetic field probe:
w
w
w
w w
Frequency range: 100kHz-3GHz
Pre-Amplifier noise (PBS2): 3.5dB typical
PreAmplifier type/gain (PBS2): "linear" falloff. 1MHz: 40dB; 500MHz: 37.5dB; 1GHz: 35dB
Dimensions of case (L/W/D): (320x250x100) mm
Weight PBS1 (case incl. probes): 1200gr
Weight PBS2 (case incl. probes and pre-amplifier): 1500gr
Warranty: 10 years
w
PBS1 & PBS2 Sniffer Set:
w
w
w
w
w
w
w w w
Perfect for locating interference sources which might have been
found e.g. in an EN55011, EN55022 or EN50371 (Class A or Class B)
survey. After implementing appropriate changes in the circuit, their efficiency
can easily and reliably be verified. That way, expensive and timeconsuming
re-assessments in an EMC laboratory can be skipped.
Verification of official EMC limits: For example, should an interference
source exceed an official EMC limit by 10dB, our probe set can easily
verify if a certain countermeasure succeeds in making the circuitry conforming
again.
This is another situation where the probe sets can eliminate the need for
expensive and time-consuming measurements in EMC laboratories.
3
Details
Magnetic field measurement on a group of components using the 60mm H-field probe
Included in delivery (PBS1)
Pinpointing interference sources on a circuit board
Our EMC probe set allows for straightforward pinpointing and
measurement of interference sources in electronic component
groups as well as execution and monitoring of generic EMC measurement.
Our probe set is especially suitable for:
- Pinpointing interference sources
- Estimation of interference field strength
- Verification of shielding and filtering measures
- Identifying faulty components
- Detecting circuitry overly sensitive to interference
Our set includes a total of 5 probes: 3 probes for magnetic field
measurement and two for measurement of electric fields. All probes
are covered with an insulating layer, thus allowing safe measurement
of oscillators or mains lines.
The PBS2 probe set additionally contains a high-performance
pre-amplifier, allowing measurement of significantly weaker interference
sources, boosting the sensitivity of our instruments by up
to 40dB.
All probes have deliberately been implemented as passive devices
 