• 热门标签

当前位置: 主页 > 航空资料 > 航空公司 >

时间:2010-07-29 10:52来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

-- FIREFIGHTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REPEAT AS NECESSARY
(*)Repeat last four steps of the procedure, as necessary.
TR1 A318/A319/A320/A321 FLEET CCOM Page 17 of 22
CABIN CREW OPERATING MANUAL
ABNORMAL/EMERGENCY PROCEDURES
FIRE PROTECTION
09.020
SEP 13/07
ALL
LAVATORY SMOKE/FIRE PROCEDURE (CONT’D)
• If situation is cleared :
-- AFFECTED LAVATORY . . . . MONITOR FOR THE REMAINDER OF THE
FLIGHT
To ensure that the lavatory remains clear of smoke.
TR1 A318/A319/A320/A321 FLEET CCOM Page 18 of 22
CABIN CREW OPERATING MANUAL
ABNORMAL/EMERGENCY PROCEDURES
FIRE PROTECTION
09.020
SEP 13/07
ALL
PAX SEAT SMOKE
The class of fire will determine how a passenger seat smoke/fire event is dealt
with. The source of smoke/fire may come the IFE screen, ISPSS outlet, or from
the seat boxes located under the passenger seats.
• If passenger seat smoke is suspected :
-- CABIN CREW . . . . INFORM AND COORDINATE WITH COCKPIT CREW
-- BASIC FIRE FIGHTING PROCEDURE . . . . . . . . . . APPLY IF NECESSARY
TR1 A318/A319/A320/A321 FLEET CCOM Page 19 of 22
CABIN CREW OPERATING MANUAL
ABNORMAL/EMERGENCY PROCEDURES
FIRE PROTECTION
09.020
SEP 13/07
ALL
GALLEY SMOKE
Galley smoke/fire occurrences can be caused by electrical equipment malfunction
for example, coffee makers, ovens, water boilers etc.
• If the source of the smoke/fire is identified from a piece of electrical
equipment:
-- ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
-- APPLICABLE CIRCUIT BREAKER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PULL
Circuit breakers are located on the galley’s centralized electrical panel.
Pulling the applicable circuit breaker should stop the smoke/fire.
• If the smoke/electrical smell source cannot be identified:
GALLEY SHUTOFF
-- MAIN GALLEY POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
-- ALL CIRCUIT BREAKERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PULL
• If the smoke/fire continues:
-- BASIC FIRE FIGHTING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . APPLY
TR1 A318/A319/A320/A321 FLEET CCOM Page 20 of 22
CABIN CREW OPERATING MANUAL
ABNORMAL/EMERGENCY PROCEDURES
FIRE PROTECTION
09.020
SEP 13/07
ALL
OVEN SMOKE
Oven smoke/fires occurrences may be caused by the oven contents, such as,
food or grease deposits. Electrical malfunctions may be another source.
-- OVEN DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KEEP CLOSED
Note: By keeping the oven door closed, the fire will usually extinguish itself.
-- OVEN POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
-- CIRCUIT BREAKER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PULL
The applicable oven circuit breaker is located on the galley’s centralized
electrical panel.
• IF SMOKE OR FIRE IS STILL PRESENT:
-- PBE AND FIRE GLOVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DON
-- OVEN DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPEN SLIGHTLY
Note: Open the oven door slightly, just enough to insert the nozzle of the
fire extinguisher into the oven.
-- (*)FIRE EXTINGUISHER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISCHARGE
-- (*)OVEN DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLOSE
-- (*)FIREFIGHTING . . . . . . . . . . . . . . . . . . . . . . . . . . . REPEAT AS NECESSARY
(*)Repeat last three steps of the procedure, as necessary.
TR1 A318/A319/A320/A321 FLEET CCOM Page 21 of 22
CABIN CREW OPERATING MANUAL
ABNORMAL/EMERGENCY PROCEDURES
FIRE PROTECTION
09.020
SEP 13/07
ALL
OVERHEAD BIN SMOKE/FIRE PROCEDURE
Smoke/fire in overhead bins may be caused by the contents or a possible
electrical malfunction in the Passenger Service Unit (PSU).
• If smoke is visibly emitting from an overhead bin:
-- BASIC FIRE FIGHTING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . APPLY
FIREFIGHTER
-- OVERHEAD BIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK FOR HEAT
Check for heat. Using the back of the hand, feel the overhead bin to
determine the temperature and presence of fire.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320_Generic_Training_CCOM 下(41)