FIRE PROTECTION
09.020
SEP 13/07
ALL
CABIN SMOKE/FIRE PROCEDURE "HIDDEN
AREA" OR "UNKNOWN SOURCE"
Smoke emissions from sidewall panels, ceiling panels and vents may indicate a
hidden fire. In some cases, smoke may appear some distance away from it’s
actual source.
-- BASIC FIRE FIGHTING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPLY
FIREFIGHTER
-- SOURCE OF SMOKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOCATE
-- REASON FOR SMOKE . . . . . . . . . . . . . . . . . . INVESTIGATE AND DETERMINE
Note: To determine the source of a potential fire, crewmembers should check for
"hot spots" on panels. Use the back of the hand along the panels to feel
for the presence of unusually hot areas.
• WHEN "HOT SPOT" IS LOCATED:
-- AREA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACCESS WITH CARE
CAUTION
When gaining access behind panels, be aware of the presence of wiring
bundles. Make a careful incision in the panel to pass extinguisher nozzle,
or lever the panel to gain access.
-- FIRE EXTINGUISHER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISCHARGE
TR1 A318/A319/A320/A321 FLEET CCOM Page 15 of 22
CABIN CREW OPERATING MANUAL
ABNORMAL/EMERGENCY PROCEDURES
FIRE PROTECTION
09.020
SEP 13/07
ALL
LAVATORY SMOKE/FIRE PROCEDURE
Lavatory smoke/fires can be caused by electrical system malfunctions for
example, the water heater, toilet vacuum, or may be caused by burning materials
usually caused by a carelessly discarded cigarette in the lavatory waste bin.
COCKPIT CREW
-- SMOKE LAVATORY SMOKE . . . . . . . . . . . . . . . . . . . . . . . . CREW AWARENESS
Maintain contact with the cabin crew to follow up on the status of the fire.
CABIN CREW PROCEDURE
On the FAP, and/or related AAP, the SMOKE warning indication comes on, with
an associated triple chime, repeated every 30 seconds (optionally 10 seconds).
-- AFFECTED LAVATORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOCATE
On all AIPs, the affected lavatory is clearly indicated and a red indicator
flashes.
The amber light, on the respective ACPs, and the outside Smoke/Pax call
indicator of the affected lavatory flashes.
Affected lavatory is also shown on the FAP Smoke page.
WARNING
Do not open the lavatory door. First, check the door for heat. Using the back
of the hand, feel the panel of the lavatory door, to determine temperature and
presence of fire.
-- LAVATORY DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK FOR HEAT
• If the door lavatory panel is cool:
-- LAVATORY DOOR . . . . . . . . . . . . . . . . . . . OPEN SLOWLY WITH CAUTION
-- SOURCE OF SMOKE/FIRE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOCATE
TR1 A318/A319/A320/A321 FLEET CCOM Page 16 of 22
CABIN CREW OPERATING MANUAL
ABNORMAL/EMERGENCY PROCEDURES
FIRE PROTECTION
09.020
SEP 13/07
ALL
LAVATORY SMOKE/FIRE PROCEDURE (CONT’D)
• If fire is present:
-- BASIC FIREFIGHTING PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPLY
Note: There is an automatic fire extinguisher installed, above the wastebin
in each lavatory.
-- FIRE EXTINGUISHER . . . . . . . . . . . . . . . . . . . DISCHARGE AT BASE OF FIRE
-- SMOKE PUSHBUTTON (ON THE FAP or AAP IN YOUR ZONE) . . RESET
To silence the chime, and reset all visual warnings on the ACPs, the AIPs.
Note: The amber Smoke indicator of the affected lavatory, the SMOKE RESET
pushbutton on the FAP and respective AAP and the indication on the
FAP Smoke page remain ON until all smoke has dissipated.
• If door panel is hot
Note: If the door is hot, the fire is at a critical stage. Have extra fire fighting
equipment available and ready to use.
-- PBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DON
-- FIREFIGHTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROTECT SELF
Stay low and crouch down, using the door panel as protection against
smoke and heat.
-- (*)LAVATORY DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPEN SLIGHTLY
Just enough to pass the nozzle of the extinguisher.
-- (*)FIRE EXTINGUISHER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISCHARGE
-- (*)LAVATORY DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLOSE
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320_Generic_Training_CCOM 下(40)