WEU Power Supply Function (Fig. 3)
(a)
The Warning Electronics Unit (WEU) power supply A receives 115 volts ac through the WARN ELEX A circuit breaker from the right unswitched ac bus. It rectifies the input ac voltage and provides +5 volts and |12 volts dc output to the warning modules.
(b)
During normal operation, the fault ball on the front of the WEU shows black. The presence of |12 volt dc also energizes the fault relay to remove the ground from the power supply failure discrete signal to the EICAS computers.
ú
31-51-00
ALL ú ú 11 Page 8 ú Jan 28/02
A
757
MAINTENANCE MANUAL
ú
31-51-00
ALL ú ú 04 Page 9 ú Jan 28/02
115V AC
R BUS
LINE LOAD
WARNELEX A
400 HZ P11
EMI FILTER
YELLOW INDICATES FAULT
BLACK INDICATES RESET POWER SUPPLY A PSU A FAULTRELAY
Warning Electronics Unit (WEU) Power Supply Schematic (Example)
Figure 3
A
757
MAINTENANCE MANUAL
(c)
Each regulated power output is monitored for an under or over voltage condition. These conditions will relax the fault relay to provide a WARN ELEX failure discrete signal to the EICAS computers. The fault ball also latches to yellow to show a fault condition.
(d)
Pressing the RESET switch on the warning electronics unit resets the fault ball to black (normal). When the Warning Electronics Unit returns to normal, the |12 volts dc is applied to the fault relay. The relay is energized, WARN ELEX failure discrete signal to the EICAS computers is removed.