(b)  
The status page consists of subsystem digital readouts and control surface positions shown on the left side of the display. Status messages are displayed along the right side of the page.
  ú
 31-41-00
 ALL  ú ú 15 Page 14 ú Dec 20/95
STATUS PAGE(BOTTOM DISPLAY)
SYMBOL  NAME SOURCEPRIME  REMARKS 
0.76 RCL RFHYD QTY 0.250.76  HYDRAULIC QUANTITY MODULEMONITORQUANTITY  REFILL (RF) IS PINK.NORMAL COLOR IS WHITE.LIMITS: 0.00 TO 1.00% FULL  
HYD PRESS 3230 21403210  HYDRAULIC PRESSURE SENSORHYD. PRES. LIMITS: 0 TO 4000 PSI 
87 OIL Q22RPMAPU EGT 640 0.75  APU PARAMETERS  SENSORSAPU  LIMITS: EGT, 0 TO 900`C 2 2OIL Q, 0 TO 1.00% FULLRPM, 0 TO 120%  
OXY PRESS  OXYGEN PRESSURE  PRESSURESYSTEMCREW OXYGEN  LIMITS: 0 TO 2500 PSI  
AILELEVAIL RUD  INDICATORSSURFACE POSITION TRANSMITTERSPOSITION  RUDDER LIMITS: -31` TO +31`ELEVATOR LIMITS: -22` TO +32`AILERON LIMITS: -21` TO +21`  
ALTFANCARGOCABIN AUTO 1  STATUS MESSAGES  VARIOUS  SEE TEXT  
PAGE 2  PAGE INDEX  COMPUTEREICAS  LIST IS FULL)(PRESENT ONLY WHEN STATUSSHOWS OVERFLOW OF STATUS MESSAGES  
2 1 2 5 1 2 1 3 BRAKE TEMP  BRAKE TEMPERATUREREADOUTS2  TEMPBRAKESENSORS  LIMITS: 0 TO 9 UNITSCOLOR: SEE TEXT 
PARAMETER VALUES AND INDICATIONS ARE FOR ILLUSTRATION PURPOSES ONLY.
GUN 051 
EICAS Displays - Status Page
Figure 4
A 
757 
MAINTENANCE MANUAL
ú
 31-41-00
 ALL  ú ú 14 Page 15 ú Jan 28/02
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 仪表 CHAPTER 31 - INSTRUMENTS 2(20)