 on the main power distribution panel, P6:
 1) 6F14, L FUEL OVRD PUMP
 2) 6F20, R FUEL OVRD PUMP
 3) 6H1, FIRE EXTINGUISHING ENG L BTL 1
 4) 6H2, FIRE EXTINGUISHING ENG L BTL 2
 5) 6H3, FIRE EXTINGUISHING ENG R BTL 1
 6) 6H4, FIRE EXTINGUISHING ENG R BTL 2
 7) 6H14, L AFT FUEL BOOST PUMP
 8) 6H17, R FWD FUEL BOOST PUMP
 9) 6H20, R AFT FUEL BOOST PUMP
 10) 6H23, L FWD FUEL BOOST PUMP

 (by) Remove the DO-NOT-CLOSE tags and close these circuit breakers on the overhead panel, P11: 1) 11D7, ENGINES STBY IGNITION LEFT 1 2) 11D8, ENGINES STBY IGNITION LEFT 2 3) 11D9, ENGINES STBY IGNITION RIGHT 1 4) 11D10, ENGINES STBY IGNITION RIGHT 2 5) 11K9, LEFT ENGINE OIL PRESS 6) 11K35, RIGHT ENGINE OIL PRESS 7) 11L1, LEFT ENGINE IGN 1 8) 11L28, RIGHT ENGINE IGN 1
 S 715-042
 (5)  EICAS Maintenance Panel Test
 (a)  
Make sure that this circuit breaker on the P11 panel is closed:

 (b)  
Make sure that this circuit breaker on the P11 panel is closed: 1) 11S15, AIR/GND SYS 1


  ú

 31-41-00
 ALL  ú ú 13 Page 514 ú Sep 28/00

A

757
MAINTENANCE MANUAL

 (c)  
Push the ECS MSG switch on the EICAS MAINT panel.

 (d)  
Make sure that the ECS/MSG page shows on the bottom display.

 (e)  
Push the PERF APU switch on the EICAS MAINT panel.

 (f)  
Make sure that the PERF/APU page shows on the bottom display.

 (g)  
Push the AUTO-READ switch on the EICAS MAINT panel.

 (h)  
Make sure that AUTO EVENT shows on the bottom of the PERF/APU page.

 (i)  
Push the MAN-READ switch on the EICAS MAINT panel.

 (j)  
Make sure that MAN EVENT shows at the bottom of the PERF/APU page.

 (k)  
Push the ENG EXCD switch on the EICAS MAINT panel.

 (l)  
Make sure that the ENG/EXCD page shows on the bottom display.

 (m)  
Push the CONF/MCDP switch on the EICAS MAINT panel.

 (n)  
Make sure that the CONF/MCDP page shows on the bottom display.

 (o)  
Push the ELEC HYD switch on the EICAS MAINT panel.

 (p)  
Make sure that the ELEC/HYD page shows on the bottom display.

 (q)  
Push the REC switch on the EICAS MAINT panel.

 (r)  
Push the MAN-READ switch on the EICAS MAINT panel.

 (s)  
Make sure that the ELEC/HYD data still shows.

 (t)  
Push the ERASE switch on the EICAS MAINT panel and hold it for 1 second.

 (u)  
Make sure that no numerical data shows on the bottom display.