(by) Remove the DO-NOT-CLOSE tags and close these circuit breakers on the overhead panel, P11: 1) 11D7, ENGINES STBY IGNITION LEFT 1 2) 11D8, ENGINES STBY IGNITION LEFT 2 3) 11D9, ENGINES STBY IGNITION RIGHT 1 4) 11D10, ENGINES STBY IGNITION RIGHT 2 5) 11K9, LEFT ENGINE OIL PRESS 6) 11K35, RIGHT ENGINE OIL PRESS 7) 11L1, LEFT ENGINE IGN 1 8) 11L28, RIGHT ENGINE IGN 1
 S 715-042
 (5)  EICAS Maintenance Panel Test
 (a)  
Make sure that this circuit breaker on the P11 panel is closed:
 (b)  
Make sure that this circuit breaker on the P11 panel is closed: 1) 11S15, AIR/GND SYS 1
  ú
 31-41-00
 ALL  ú ú 13 Page 514 ú Sep 28/00
A
757 
MAINTENANCE MANUAL
 (c)  
Push the ECS MSG switch on the EICAS MAINT panel.
 (d)  
Make sure that the ECS/MSG page shows on the bottom display.
 (e)  
Push the PERF APU switch on the EICAS MAINT panel.
 (f)  
Make sure that the PERF/APU page shows on the bottom display.
 (g)  
Push the AUTO-READ switch on the EICAS MAINT panel.
 (h)  
Make sure that AUTO EVENT shows on the bottom of the PERF/APU page.
 (i)  
Push the MAN-READ switch on the EICAS MAINT panel.
 (j)  
Make sure that MAN EVENT shows at the bottom of the PERF/APU page.
 (k)  
Push the ENG EXCD switch on the EICAS MAINT panel.
 (l)  
Make sure that the ENG/EXCD page shows on the bottom display.
 (m)  
Push the CONF/MCDP switch on the EICAS MAINT panel.
 (n)  
Make sure that the CONF/MCDP page shows on the bottom display.
 (o)  
Push the ELEC HYD switch on the EICAS MAINT panel.
 (p)  
Make sure that the ELEC/HYD page shows on the bottom display.
 (q)  
Push the REC switch on the EICAS MAINT panel.
 (r)  
Push the MAN-READ switch on the EICAS MAINT panel.
 (s)  
Make sure that the ELEC/HYD data still shows.
 (t)  
Push the ERASE switch on the EICAS MAINT panel and hold it for 1 second.
 (u)  
Make sure that no numerical data shows on the bottom display.