• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-10-28 12:43来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Page 2008
B/E AEROSPACE
COMPONENT MAINTENANCE MANUAL MILLENNIUM. 88813 SERIES
(b)  Select the smallest clamp size that:.
1

Holds the wiring securely,
2

Allows no abrasive movement, and
3

Neither crushes nor pinches the wire.
(c)  
Use standard clamps. Clamping and installation should be done in a way that facilitates the removal and replacement of cable assemblies.

(d)  
Tie and support wire or cable bundles to prevent mechanical strain on individual wires or terminations.

(e)  
When the diameter of the cable is smaller than what the clamp can securely hold, use nylon tape to wrap the cable before clamping.

(f)  
Do not use hook and loop fasteners to secure cable bundles.


(8)  Connectors
(a)  
Minimize the handling of connectors and cabling at all times to reduce the possibility of connector damage.

(b)  
Minimize the bending of wire conductors. Cables containing any wire with damaged insulation should be replaced.

(c)  
Wiring should be periodically inspected for signs of unacceptable damage such as cuts, breaks, cracked or burnt insulation or excessive kinks.

(d)  
Periodically inspect connectors for signs of contamination with metal particles, water, dirt, grease, oil, carbon or adhesive.

(e)  
Periodically inspect connectors for bent or corroded contacts. Do not straighten bent connector contacts. Do not reject tarnished silver, gold or rhodium plating on contacts.

(f)  
Use standard snug fitting dust caps to protect the uncoupled end of connectors from mechanical damage and contamination. Install the dust covers on all connectors to prevent damage.

(g)  
When performing service requiring disconnecting connectors, protect connectors from contamination by metal particles, water, dirt, grease and oil. Use polyethylene bags.

(h)  
Route cables to minimize mechanical strain on connectors and cabling.

(j)  
Protect cables against breakage at connections by providing enough slack and using mechanical clamping as needed to relieve strain.


Page 2009
B/E AEROSPACE
COMPONENT MAINTENANCE MANUAL
MILLENNIUM. 88813 SERIES

(k)  
Install connectors to prevent their usage as steps, hand holds, or footrest, and to prevent mechanical strain on attached cables.

(l)  
Securely attach each connector on the seat structure using one of the following methods:


1  Plastic straps (Tyraps, Panduit, etc.)
2  Clamps
3  Structure provision (raceway, bracket, etc.).
(m)  Mount connectors horizontally to allow for drainage and prevent the trapping of liquid or condensation.
(9) Handling of ESD (Electrostatic Discharge)-Sensitive Parts and Assemblies
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:MILLENNIUM™ 88813 SERIES PASSENGER SEATS 旅客座椅(15)