• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-10-21 11:48来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

8 - Purging valve
9 - Charging cylinder pressure gage
10 - Oil injector by-pass tee
11 - Oil injector
12 - Charging cylinder
13 - Vacuum pump
14 - Vacuum pump ON / OFF switch
15 - Heating element ON / OFF switch
16 - Oil level sight glass
17 - Oil filling plug
18 - Oil bottle
19 - Oil injector by-pass tee hand valve
20 - Fluoro-dye injector hand valve
21 - Fluoro-dye injector filling plug
22 - Fluoro-dye injector
23 - Vacuum pump "VAC" hand valve
24 - Low pressure "LOW" hand valve
25 - Low pressure gage
System charging - Schematic
Key to Figure 301
AAAA
Validity : Vapor cycle cooling system - KEITH 12-15-01Page 306
(BA) JUN 02
 

 
PAGE INTENTIONALLY LEFT BLANK
AAAA
Validity : Vapor cycle cooling system - KEITH 12-15-01Page 308
(BA) JUN 02
 
REFRIGERANT DISCHARGING
SERVICING
1. SYSTEM DISCHARGING (Figure 301)
A. Tools and consumable materials
- Charging cart KLIMAX 134 PR4 type or equivalent
- Recycling stand KLIMAX 1500 type or equivalent
- Safety goggles and gloves
- Lint-free clean cloths
B. Procedure
WARNING : OBEY SAFETY USE PRECAUTIONS - refer to 12-15-00.
1) Park the aircraft in a well ventilated area.
2) Position the recycling stand and the charging cart near the aircraft.
NOTE : The recycling stand must be higher than the charging cart to allow complete system discharging.
3) Remove baggage compartment bottom door 242.
4) Remove blanking caps.
5) Connect a hose on the recycling stand "IN" union.
6) Connect the hose opposite end to the LP service valve.
7) Connect a hose on the recycling stand "OUT" union.
8) Connect the hose opposite end to the charging cart HP union.
9) Open the charging cart "HIGH" and "REF" hand valves.
10) Set the recycling stand switch to "ON" and verify that the green indicator light illuminates.
NOTE : The recycling stand will discharge the system, separate the oil from the refrigerant and will store it into the charging cylinder.
11) When the pressure becomes negative, empty system, the recycling stand will stop automatically.
12) Observe the gage and restart the stand if the pressure increases.
13) Close the charging cart "REF" and "HIGH" hand valves.
14) Disconnect hoses and install blanking caps.
15) Remove blanking cap from recycling stand "OIL" fitting.
16) Collect drained oil in a measuring jar and record the quantity.
17) Discard the drained oil.
18) Install blanking cap on the "OIL" fitting.
19) Remove the recycling stand and the charging cart.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TB20 MAINTENANCE MANUAL 12 SERVICING TB20飞机维护手册 12 保养(48)