Measured pressure Actions
0.99 P to 0.95 P Inflate to P.
0.95 P to 0.90 P Inflate to P. Check after 24 hours. If pressure loss is greater than 0.05 P, check for cause of pressure loss.
0.90 P to 0.80 P Remove wheel - refer to 32-41-01 or 32-41-02. Inflate to P. If pressure loss is greater than 0.05 P a day, check for cause of pressure loss.
0.80 P to 0 Remove wheel - refer to 32-41-01 or 32-41-02. Check for cause of pressure loss. Replace tire if necessary.
6) Remove the inflation hose.
7) Using soapy water, check inflation valve (2) for leaks.
8) Install valve cap (1) on inflation valve (2).
9) Make sure all the tools and materials are removed and the work area is clean and free from debris.
AEAC
Validity : S / N 1 - 9999 12-14 01Page 302
(DA) SEP 04
1 - Valve cap
2 - Inflation valve
AEAC
Validity : S / N 1 - 9999 12 14-01Page 303