T/O V = 108 ktsLDG V FE = 91 kts
FE
GTX 327 IDENT FUNC CRSR
GARMIN
ON
PRESSURE ALT
1200
ALT ALTmax.
START
12300 f
108 KIAS
tVFR R
CLR
STOP
max.
91 KIAS
01234 567 89
%

%
5252570303 3 5 5 510101010 25510152 3 3 3 105 325103 3 5155 3302
14 VDC ACCESSORY PWR GROUND OPS. ONLY 2A MAX
%
%
%
%
%
%
%
%
%
%

5252570303 3 5 5 5
%
%
%
%
%

10101010 25 5 1015 2 3
%
%
%
%
%
%
%

3 3 105 3
%

14 VDC ACCESSORY PWR
%

GROUND OPS. ONLY 2A MAX
%
%

25103 3 5155 3302
% % % % % Figure 2: Electrical Switches and Circuit-Breakers %
Doc # 6.02.01 Page 3
Rev. 4 09 Jan 2003

24-61-00
AMM

% Intentionally left blank
24-61-00
Electrical Power
AMM

%  Trouble-Shooting 
%  1. General 
%  Make sure that the alternator is supplying power and that there is 14 VDC on the Main Bus. Refer to 
%  Section 24-33. For faults on a piece of equipment, or a system, refer to the applicable Chapter. For 
%  example, for no oil pressure indication, see Chapter 77 Engine Indicating. The table below lists the 
%  defects you could have with the DC load distribution system. If you have the trouble detailed in the 
%  Trouble column, read across to the Possible Cause column. Then do the repair given in the Repair 
%  column. 

%

%
%

%
%

%
%

%
%
%
%
%

%
%
%

%
%

%
%

%
%
%
%
%

Trouble  Possible Cause  Repair 
There is 14 VDC on the main  Avionic master switch set to  Set the avionic master switch 
bus but not on the avionic bus.  OFF. AV. BUS circuit-breaker not set. Avionics master relay defective. A failure of the cables which connect the main bus to the avionics bus.  to ON. Set the AV. BUS circuit breaker. Replace the avionics master relay. Do a continuity test of the cables. Refer to Chapter 92 for the wiring diagrams. Repair/replace defective cables. 
There is 14 VDC on the  Avionic master switch set to  Set the avionic master switch 
essential bus but not on the  OFF.  to ON. 
essential avionic bus.  ESS AV. circuit-breaker not set. Essential avionics relay defective. A failure of the cables which connect the essential bus to the essential avionic bus.  Set the ESS AV. circuit-breaker. Replace the essential avionics relay. Do a continuity test of the cables. Refer to Chapter 92 for the wiring diagrams. Repair/replace defective cables. 

%

Doc # 6.02.01 Page 101
Rev. 4 09 Jan 2003

24-61-00
AMM

%
%

%
%

%
%

%
%

%

%

%
%
%

%
%
%
%
%
%

%
%

%
%

%

%
%

%
%

%
%
%

%

%

%
%
%
%
%
%

%
%
%

DA 40 Series

Trouble  Possible Cause  Repair 
There is 14 VDC on the main  MAIN TIE circuit-breaker not  Set the MAIN TIE circuit 
bus but not on the essential  set.  breaker. 
bus with the essential bus  ESS TIE circuit-breaker not  Set the ESS TIE circuit 
switch set to OFF.  set. Essential tie relay defective. A failure of the cables which connect the main bus to the essential tie relay and essential bus.  breaker. Replace the essential tie relay. Do a continuity test of the cables. Refer to Chapter 92 for the wiring diagrams. Repair/replace defective cables. 
 