Doc # 6.02.01 Page 201
Rev. 4 09 Jan 2003
24-40-00
AMM
Detail Steps/Work Items Key Items/References
(4) Disconnect the electrical cables from the external power relay.
(5) Remove the 2 bolts which attach the external power relay to the relay box.
(6) Move the relay clear of the airplane.
B. Install the External Power Relay
Detail Steps/Work Items Key Items/References
(1) Put the relay in position in the relay box.
(2) Install the 2 attaching bolts.
(3) Connect the power and control cables to the external power relay. Refer to Chapter 92 for the wiring diagrams.
(4) Install the cover to the relay box.
(5) Connect the positive cable to the battery. Apply Dow Corning compound (DC4) to the battery terminal and the cable lug.
(6) Connect the negative cable to the battery. Apply Dow Corning compound (DC4) to the battery terminal and the cable lug.
(7) Install the engine cowlings. Refer to Section 71-10.
(8) Do a function test of the external power relay: S Connect an 28 V DC external power supply to the external power socket. S Set the ALT/BAT switch to ON. S The airplane voltmeter must show 28 V. S Remove the external power supply. S The airplane voltmeter must show 24 V. S Set the ALT/BAT switch to OFF.
Page 202 Doc # 6.02.01 09 Jan 2003 Rev. 4
24-40-00
Electrical Power
AMM
% Section 24-41 % External Power - TAE 125 Diesel Engine % 1. General
% The DA 40 has an external power socket located on the left side of the fuselage, near the relay % junction box. It is a standard 14 Volt DC power socket. When you connect external power to the % external power socket, the external power control relay is energized and the external power comes % on-line.
% 2. Description and Operation
% Figure 1 shows a simple schematic diagram of the external power system. The external power system % has these components:
% A. 14 Volt Socket
% The 14 VDC power socket is located on the left side of the fuselage, near the relay junction box. % The socket has 3 pins:
%) A large negative pin.
%) A large positive pin.
%) A small positive pin.
% A diode connected between the small positive pin and the external power relay solenoid protects % the system from reverse polarity.
% B. External Power Relay