C. Procedure
S 862-002-N00
(1)
Open this circuit breaker on the main power distribution panel, P6, and attach the DO-NOT-CLOSE tag:
(a) 6J18, ENG START AIR CONT
(2)
Open the core cowl panels (AMM 71-11-06/201).
S 012-003-N00
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
80-11-04
ALL ú ú N01 Page 201 ú Oct 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / PW4000 SERIES /747-400 / ENGINES /MAINTENANCE MANUAL ////////////////////////
SEE A
SEE B
START VALVE
PACKING GEARBOX MAIN
BUSHING A STARTER FWD
VALVE START
PNEUMATIC TUBE SENSING FILTER FWD
B
Figure 201 Start Valve Filter Installation
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
80-11-04
ALL ú ú N01 Page 202 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
S 022-033-N00
(3) Do these steps to remove the filter (Fig. 201):
(a)
Disconnect the tube nut from the filter boss on the case of the start valve.
(b)
Pull the other end of the tube out.
(c)
Discard the packing from the bushing end.
(d)
Remove the filter from the boss.
TASK 80-11-04-102-009-N00
3. Clean the Start Valve Filter____________________________
A. Standard Tools and Equipment
(1) Air Source - Compressed, Clean, Filtered, Dry - 30 psi (200 kPa) maximum
B. Consumable Materials
(1) B00722 Solvent - P-D-680
C. References
(1) IPC 80-11-02 Fig. 1
D. Access
(1)
Location Zone
412 Engine No. 1
422 Engine No. 2
432 Engine No. 3
442 Engine No. 4
(2)
Access Panel
417 and 418 Core Cowl Panels - Engine No. 1
427 and 428 Core Cowl Panels - Engine No. 2
437 and 438 Core Cowl Panels - Engine No. 3
447 and 448 Core Cowl Panels - Engine No. 4
E. Procedure
S 022-010-N00
(1) Remove the start valve filter, if it is necessary.
S 112-036-N00
WARNING: DO NOT GET THE SOLVENT IN YOUR MOUTH OR EYES, OR ON YOUR SKIN.
_______ DO NOT BREATHE THE FUMES FROM THE SOLVENT. PUT PROTECTIVE SPLASH GOGGLES AND GLOVES ON WHEN YOU USE THE SOLVENT. KEEP THE SOLVENT AWAY FROM SPARKS, FLAME, AND HEAT. THIS SOLVENT IS POISONOUS AND FLAMMABLE AND CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
(2) Clean the filter with the solvent.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
80-11-04
ALL ú ú N01 Page 203 ú Oct 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / PW4000 SERIES /747-400 / ENGINES/MAINTENANCE MANUAL ////////////////////////
S 162-037-N00
WARNING:_______USE GOGGLES WHEN YOU USE COMPRESSED AIR. PARTICLES WHICH ARE
BLOWN BY THE COMPRESSED AIR CAN CAUSE INJURY TO YOU.
CAUTION: BE CAREFUL WHEN YOU USE COMPRESSED AIR TO CLEAN THE MESH OF THE
_______ FILTER SCREEN. COMPRESSED AIR CAN CAUSE DAMAGE TO THE MESH OF THE FILTER SCREEN.
(3)
Use the compressed air at not more than 30 psig to dry the filter.
S 212-014-N00
(4)
Make sure there is no unwanted material in the filter.
(a) If you find unwanted material in the filter, clean the filter again.
S 422-015-N00
(5) Install the start valve filter.
TASK 80-11-04-402-016-N00
4. Install the Start Valve Filter
______________________________
A. Consumable Materials
(1)
D00341 Lubricant - Sanovac 5
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 起动 STARTING(18)