Sep 01/02 28-00 Page 205

5.  Fuel System Static Bond Path, No. 2 Tank - Inspection
A.  References
(1)  
AMM 28-10-0/201, Fuel Tanks

(2)  
AMM 28-11-11/401, Wing Fuel Tank Access Panels

(3)  
DWG 65-48404, R.H. INBD. INSPAR AREA, W.B.L. 72.24 - 227

(4)  
DWG 65-48406, R.H. OUTBD. INSPAR AREA, W.B.L. 227 TO TIP


B.  Procedure
(1)  
For the area in the No. 2 fuel tank between rib No. 1 (side-of-body rib at WBL 71.24) and rib No. 5 (rib at WBL 157.00), do these steps:

(a)  
Remove access panel No. 1 on the right wing (AMM 28-11-11/401).

(b)  
Go into the opening for access panel No. 1 (AMM 28-10-0/201).

(c)  
Do this task for all bonding jumpers between rib No. 1 and rib No. 5: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48404 for bonding jumper locations.

(d)  
If access is not necessary for subsequent tasks, install access panel No. 1   (AMM 28-11-11/401).

 

(2)  
For the area in the No. 2 fuel tank between rib No. 5 (rib at WBL 157.00) and rib No. 7 (rib at WBL 198.60), do these steps:

(a)  
Remove access panel No. 2 on the right wing (AMM 28-11-11/401).

(b)  
Go into the opening for access panel No. 2 (AMM 28-10-0/201).

(c)  
Do this task for all bonding jumpers between rib No. 5 and rib No. 7: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48404 for bonding jumper locations.

(d)  
If access is not necessary for subsequent tasks, install access panel No. 2   (AMM 28-11-11/401).

 

(3)  
For the area in the No. 2 fuel tank between rib No. 7 (rib at WBL 198.60) and rib No. 8 (rib at WBL 227.00), do these steps:

(a)  
Remove access panel No. 3 on the right wing (AMM 28-11-11/401).

(b)  
Go into the opening for access panel No. 3 (AMM 28-10-0/201).

(c)  
Do this task for all bonding jumpers between rib No. 7 and rib No. 8: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48404 for bonding jumper locations.

(d)  
If access is not necessary for subsequent tasks, install access panel No. 3   (AMM 28-11-11/401).

 

(4)  
For the area in the No. 2 fuel tank between rib No. 8 (rib at WBL 227.00) and rib No. 9 (rib at WBL 254.00), do these steps:

(a)  
Remove access panel No. 4 on the right wing (AMM 28-11-11/401).

(b)  
Go into the opening for access panel No. 4 (AMM 28-10-0/201).

(c)  
Do this task for all bonding jumpers between rib No. 8 and rib No. 9: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48406 for bonding jumper locations.

(d)  
If access is not necessary for subsequent tasks, install access panel No. 4   (AMM 28-11-11/401).

 


500 28-00    Sep 01/02 Page 206

(5)  
For the area in the No. 2 fuel tank between rib No. 9 (rib at WBL 254.00) and rib No. 10 (rib at WBL 279.25), do these steps:

(a)  
Remove access panel No. 5 on the right wing (AMM 28-11-11/401).

(b)  
Go into the opening for access panel No. 5 (AMM 28-10-0/201).

(c)  
Do this task for all bonding jumpers between rib No. 9 and rib No. 10: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48406 for bonding jumper locations.

(d)  
If access is not necessary for subsequent tasks, install access panel No. 5   (AMM 28-11-11/401).

 

(6)  
For the area in the No. 2 fuel tank between rib No. 10 (rib at WBL 279.25) and rib No. 11 (rib at WBL 304.50), do these steps:

(a)  
Remove access panel No. 6 on the right wing (AMM 28-11-11/401).

(b)  
Go into the opening for access panel No. 6 (AMM 28-10-0/201).

(c)  
Do this task for all bonding jumpers between rib No. 10 and rib No. 11: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48406 for bonding jumper locations.

(d)  
If access is not necessary for subsequent tasks, install access panel No. 6   (AMM 28-11-11/401).

 

(7)  
For the area in the No. 2 fuel tank between rib No. 11 (rib at WBL 304.50) and rib No. 12 (rib at WBL 329.75), do these steps:

(a)  
Remove access panel No. 7 on the right wing (AMM 28-11-11/401).

(b)  
Go into the opening for access panel No. 7 (AMM 28-10-0/201).

(c)  
Do this task for all bonding jumpers between rib No. 11 and rib No. 12: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48406 for bonding jumper locations.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737 AMM 飞机维护手册 燃油 FUEL(9)