A. Apply a coat of Dow Corning No. 4 silicone grease to the external probe surfaces.
B. Grasp temperature bulb by locking cap and insert into bulb housing.
C. Push bulb in until stopped by pin.
D. Rotate locking cap to lock around pin.
E. Splice temperature bulb leads to wiring.
F. Close IND-TEMP circuit breaker on panel P6-3.
G. Provide electrical power (Ref 24-22-0 MP) and observe fuel temperature on indicator.
H. Remove electrical power (Ref 24-22-0 MP), if no longer required.
500 
Jun 20/88  BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.  28-43-11 Page 401 


Fuel Temperature Bulb Installation  500 
28-43-11  Figure 401  Jun 20/83 