D295 socket 47 and D291 socket 12 
D295 socket 9 and D291 socket 10 
.  Verify connection to ground: D295 socket 1 
D291 socket 9 at the rudder power control unit position transducer 
.  Inspect electrical connectors for bent or broken pins, contamination, or damage. 
.  If problem persists, replace rudder power control unit. Note that rudder power control unit -3, -4, -5, -8 is not compatible with -100/200/200 ADV RIDE QUALITY yaw damper installation, reference Boeing 737 Service Letter 737-SL-27-050. 
.  If problem persists, replace yaw damper coupler. 

500 
22-12-01 Page 112  BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details.  May 01/99 


A hyd not on PR off fault  msg. no. 22-21020 msg. no. 22-21021   A hyd/PR /PR snsr  PR/ A hyd /PR snsr  LATCHED: NO LATCHED: NO  Possible Causes: . Low pressure in A system hydraulics during YDC BITE pressure reducer test . Pressure reducer bypass valve . Yaw damper coupler Troubleshooting: . Verify resistance from D295 socket 31 to ground is 60 ohms. . Verify wiring between D295 socket 31 and D7377 socket 1 at the pressure reducer bypass valve solenoid. . Verify connection to ground from D7377 socket 2 at the pressure reducer bypass valve solenoid. . Verify wiring at the pressure reducer bypass valve: D295 socket 51 and D737 socket 3 D295 socket 52 and D737 socket 2 . Verify connection to ground from D737 socket 1 at the pressure reducer bypass valve. . Inspect electrical connectors for bent or broken pins, contamination, or damage. . If problem persists, replace the pressure reducer bypass valve. . If problem persists, replace yaw damper coupler. Possible Causes: . Low pressure in A system hydraulics during YDC BITE pressure reducer test . Pressure reducer bypass valve . Yaw damper coupler Troubleshooting: . Verify resistance from D295 socket 31 to ground is 60 ohms. . Verify wiring between D295 socket 31 and D7377 socket 1 at the pressure reducer bypass valve solenoid. . Verify connection to ground from D7377 socket 2 at the pressure reducer bypass valve solenoid. . Verify wiring at the pressure reducer bypass valve : D295 socket 51 and D737 socket 3 D295 socket 52 and D737 socket 2 . Verify connection to ground from D737 socket 1 at the pressure reducer bypass valve. . Inspect electrical connectors for bent or broken pins, contamination, or damage. . If problem persists, replace the pressure reducer bypass valve. . If problem persists, replace yaw damper coupler. 

500 
May 01/99  22-12-01 
Page 113 
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. 


PR on  msg. no.   PR /PR  LATCHED:  Possible Causes: 
fault  22-21022  snsr  NO  . Hydraulic pressure not reduced in A system hydraulics during YDC BITE pressure reducer test . Pressure reducer bypass valve . Yaw damper coupler Troubleshooting: . Verify that the rudder pressure reducer valve manual lever is in the normal position. . Verify resistance from D295 socket 31 to ground is 60 ohms. . Verify wiring between D295 socket 31 and D7377 socket 1 at the pressure reducer bypass valve solenoid. . Verify connection to ground from D7377 socket 2 at the pressure reducer bypass valve solenoid. . Verify wiring at the pressure reducer bypass valve : D295 socket 51 and D737 socket 3 D295 socket 52 and D737 socket 2 . Verify connection to ground from D737 socket 1 at the pressure reducer bypass valve. . Inspect electrical connectors for bent or broken pins, contamination, or damage. . If problem persists, replace the pressure reducer bypass valve. . If problem persists, replace yaw damper coupler. 
prgm pin fault  msg. no. 22-21023   prgm pin /YDC  LATCHED: NO  Possible Causes: . Program pins do not match aircraft type selected during YDC BITE program pin test. . Operator error . Aircraft wiring . Yaw damper coupler Troubleshooting: . Inspect D295 socket 17, D295 socket 53, and YDC electrical connector for bent or broken pins, contamination, or damage. . Verify D295 socket 17 and D295 socket 53 resistance to ground is consistent with aircraft wiring diagrams, summarized; 737 MODEL D295 - 53 D295 - 17 -100/200/200 ADV GROUND OPEN RIDE QUALITY -100/200/200 ADV OPEN OPEN . Perform the yaw damper coupler installation test, ref AMM12-12-01, page 401 step 4. . If problem persists, replace yaw damper coupler. 

500 
22-12-01  May 01/00 
Page 114 
BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. 


A hyd lo  msg. no.  lamp/YDC  LATCHED:  Possible Causes: 
on fault  22-21025  /wiring  NO  . Flt control A low pressure light did not illuminate during YDC BITE pressure reducer test . Operator error . Flt control A low pressure light inoperative . Yaw damper coupler Troubleshooting: . Verify that flt control A switch is in the ON position. . Verify that flt control A light illuminates, press to test. . Verify wiring between D295 socket 57 and flt control A low pressure light. . Inspect D295 socket 57 and YDC electrical connector for bent or broken pins, contamination, or damage. . Perform the yaw damper coupler installation test, ref AMM12-12-01, page 401 step 4. . If problem persists, replace yaw damper coupler. 
 