NOTE : The APU SHUTDOWNS report gives the maintenance message:
____
AIR INTAKE NOT OPEN - AIR INTAKE FLAP ACTR
- replace the AIR INTAKE-FLAP ACTUATOR (4015KM) (Ref. AMM TASK 49-16-51-000-001) and (Ref. AMM TASK 49-16-51-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-003, 051-099, 401-499, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page B211
Config-1 Aug 01/05 CES
(1) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).
(2) If the fault continues:
- do a check and repair the wiring from the ECB (59KD) AC/5, 4 to the electrical connector 7527VCA/J, K (Ref. ASM 49-16/01).
- do a check and repair the wiring from the ECB (59KD) AB/G2, G3, G4, G5 to the electrical connector 7527VCA/D, C, E, B. (Ref. ASM 49-16/01).
- do a check and repair the wiring from the electrical connector 7527VCA/A, L, F, to the ground (Ref. ASM 49-16/01).
R **ON A/C 001-003, 051-099, 401-499,
B. Do the test given in para. 3.
R **ON A/C 063-099, 401-499,
TASK 49-00-00-810-864
Oil Level Switch Fault (GTCP 36-300)
1. Possible Causes
_______________
- OIL LEVEL SWITCH (8087KM)
- wiring
- ECB (59KD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 49-00-00-710-004 Operational Test of the APU (4005KM) (GTCP 36-300) AMM 49-61-34-000-001 Removal of the Electronic Control Box (ECB) (59KD) (GTCP 36-300) AMM 49-61-34-400-001 Installation of the Electronic Control Box (ECB) (59KD) (GTCP 36-300) AMM 49-93-16-000-001 Removal of the Oil Level Switch (8087KM) (GTCP 36-300) AMM 49-93-16-400-001 Installation of the Oil Level Switch (8087KM) (GTCP 36-300) ASM 49-61/02
3. Fault Confirmation
__________________
A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-004).
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
OIL LEVEL SWITCH (8087KM)
with the LRU TROUBLE SHOOT DATA menu information:
OIL QUANTITY SWITCHES DISAGREE
Fault Code Number: 089
- replace the OIL LEVEL SWITCH (8087KM) (Ref. AMM TASK 49-93-16-000-001) and (Ref. AMM TASK 49-93-16-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the ECB (59KD) AB/H1,H2,H3 to the OIL LEVEL SWITCH (8087KM) P8/1,2,3 (Ref. ASM 49-61/02).
(a) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).
B. Do the test given in para. 3.
TASK 49-00-00-810-865
APU AVAILABLE signal fault (GTCP 36-300)
1. Possible Causes
_______________
- RELAY - APU AVAIL (6KD)
- wiring
- ECB (59KD)
- RELAY-BOARD ANN LT TEST (7LP)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 33-14-00-710-001 Operational Test of the Annunciator Light Test System in the Cockpit
AMM 33-14-33-000-001 Removal of the Annunciator-Light Test and Interface-Board (1LP, 2LP, 3LP, 4LP, 5LP, 6LP, 7LP, 8LP, 9LP, 10LP, 11LP, 12LP, 18LP, 19LP, 20LP)
AMM 33-14-33-400-001 Installation of the Annunciator-Light Test and Interface-Board (1LP, 2LP, 3LP, 4LP, 5LP, 6LP, 7LP, 8LP, 9LP, 10LP, 11LP, 12LP, 18LP, 19LP, 20LP)
AMM 49-00-00-710-001 Self-Test of the ECB (59KD) (GTCP 36-300) AMM 49-61-34-000-001 Removal of the Electronic Control Box (ECB) (59KD) (GTCP 36-300) AMM 49-61-34-400-001 Installation of the Electronic Control Box (ECB) (59KD) (GTCP 36-300) ASM 49-61/00
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 机载辅助动力 1(77)