 ASM 49-42/01
 AWM 49-42-01

 3. Fault Confirmation
__________________
 A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-008).
 4. Fault Isolation
_______________
 A. If the APU Last Leg Report gives the maintenance message:
 ACFT BAT NOT SELECTED / CONTACTOR (5KA)
 Fault Code Number: 085

 select the A/C batteries ON:
 - check and repair the aircraft wiring from the ECB (59KD) AC/1 to the START CONTACTOR (5KA) B/3 (Ref. ASM 49-42/01).
 (1) If the fault continues:
 - do a check for a ground signal (with APU MASTER SW pushed) at the MAIN START CONTACTOR (5KA) B/5 (Ref. ASM 49-42/01).
 (a) If there is a ground signal:
 - replace the CONTACTOR-MAIN START (5KA).
 1 If the fault continues:


 