- do a check and repair the wiring from the ECB (59KD) AC/5, 4 to the electrical connector 7527VCA/J, K. (Ref. ASM 49-16/01).
- do a check and repair the wiring from the ECB (59KD) AB/G2, G3, G4, G5 to the electrical connector 7527VCA/D, C, E, B. (Ref. ASM 49-16/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-106, 108-149, 211-299, 301-399, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page 270
Config-2 Aug 01/05 CES
- do a check and repair the wiring from the electrical connector 7527VCA/A, L, F, to the ground (Ref. ASM 49-16/01).
(a) If the fault continues:
- replace the AIR INTAKE FLAP-ACTUATOR (4015KM) (Ref. AMM TASK 49-16-51-000-002) and (Ref. AMM TASK 49-16-51-400-002).
1_ If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and
(Ref. AMM TASK 49-61-34-400-002).
(2) If the APU Last Leg Report gives the maintenance message:
INLET FLAP ACTR (4015KM) Fault Code Number: 058 or 120
- do a visual check of the Air-Intake (Ref. AMM TASK 49-16-00-210-002).
(a) If the fault continues:
- do a check and repair the wiring from the ECB (59KD) AC/5, 4 to the electrical connector 7527VCA/J, K. (Ref. ASM 49-16/01).
- do a check and repair the wiring from the ECB (59KD) AB/G2, G3, G4, G5 to the electrical connector 7527VCA/D, C, E, B. (Ref. ASM 49-16/01).
- do a check and repair the wiring from the electrical connector 7527VCA/A, L, F, to the ground (Ref. ASM 49-16/01).
1 If the fault continues:
_
- replace the AIR INTAKE FLAP-ACTUATOR (4015KM) (Ref. AMM TASK 49-16-51-000-002) and (Ref. AMM TASK 49-16-51-400-002).
a If the fault continues:
_
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002).
B. Do the test given in para. 3.
TASK 49-00-00-810-911 ECB 59KD Fault (APS 3200)
1. Possible Causes
_______________
- ECB (59KD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 49-00-00-710-008 Operational Test of the APU (APS 3200) AMM 49-61-34-000-002 Removal of the Electronic Control Box (ECB) (59KD) (APS 3200) AMM 49-61-34-400-002 Installation of the Electronic Control Box (ECB) (59KD) (APS 3200)
3. Fault Confirmation
__________________
A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-008).
4. Fault Isolation
_______________
A. If the APU Last Leg Report gives the maintenance message:
ECB 59KD: Fault Code Number: 024 or 064 or 066 or 071 or 073 or 082 or 089 or 100 or 101 or 107 or 117
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002).
B. Do the test given in para. 3.
TASK 49-00-00-810-912
Oil Filter Indication (APS 3200)
1. Possible Causes
_______________
- GEN-APU (8XS)
- GENERATOR SCAVENGE-FILTER (8069KM)
- LUBRICATION FILTER (8076KM)
- DIFFERENTIAL PRESSURE INDICATOR-SWITCH (8069KM)
- DIFFERENTIAL PRESSURE INDICATOR-SWITCH (8076KM)
- wiring
- ECB (59KD)
- AUXILIARY POWER UNIT (4005KM)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 24-23-51-000-001 Removal of the APU Generator 8XS
AMM 24-23-51-400-001 Installation of the APU Generator 8XS
AMM 49-00-00-710-008 Operational Test of the APU (APS 3200)
AMM 49-11-11-000-003 Removal of the Power Plant (APU) (APS 3200)
AMM 49-11-11-400-003 Installation of the Power Plant (APU) (APS 3200)
AMM 49-61-34-000-002 Removal of the Electronic Control Box (ECB) (59KD)