Load Control-Valve Fault (GTCP 36-300)
1. Possible Causes
_______________
- LOAD CONTROL VALVE P12
- wiring
- ECB (59KD)
- LOAD CONTROL VALVE (8050KM)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 49-00-00-710-001 Self-Test of the ECB (59KD) (GTCP 36-300) AMM 49-51-51-000-001 Removal of the Bleed Load Control-Valve (8050KM) (GTCP 36-300) AMM 49-51-51-400-001 Installation of the Bleed Load Control-Valve (8050KM) (GTCP 36-300) AMM 49-61-34-000-001 Removal of the Electronic Control Box (ECB) (59KD) (GTCP 36-300) AMM 49-61-34-400-001 Installation of the Electronic Control Box (ECB) (59KD) (GTCP 36-300) ASM 49-61/02
3. Fault Confirmation
__________________
A. Do the self-test of the ECB (Ref. AMM TASK 49-00-00-710-001).
4. Fault Isolation
_______________
**ON A/C 001-003, 051-062,
A. If the test gives the maintenance message:
LOAD CTL VALVE P12:
- replace the LOAD CONTROL VALVE P12 (Ref. AMM TASK 49-51-51-000-001) and (Ref. AMM TASK 49-51-51-400-001).
(1) If the fault continues:
- disconnect connector P7 from the LOAD CONTROL VALVE P12 and check for a ground signal at pin P7/1 and P7/2. Do a repair if necessary (Ref. ASM 49-61/02).
- do a check and repair the wiring from the ECB (59KD) AB/F10, F11 to the LOAD CONTROL VALVE P12/1, 2 (Ref. ASM 49-61/02).
- do a check and repair the wiring from the ECB (59KD) AB/D7, D14 to the LOAD VALVE POSITION SWITCH P7/3, 4 (Ref. ASM 49-61/02).
(2) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).
R **ON A/C 063-099, 401-499,
A. If the test gives the maintenance message:
LOAD CONTROL VALVE (8050KM)
with the LRU TROUBLE SHOOT DATA menu information:
LOAD CONTROL VALVE SHOWS OPEN SWITCH FAILURE
Fault Code Number: 096
or
LOAD CONTROL VALVE SHOWS CLOSED SWITCH FAILURE
Fault Code Number: 097
or
LOAD CONTROL VALVE SHOWS NOT OPEN
Fault Code Number: 088
or
LOAD VALVE SOLENOID SHOWS CIRCUIT FAILURE
Fault Code Number: 127
- replace the LOAD CONTROL VALVE (8050KM) (Ref. AMM TASK 49-51-51-000-001) and (Ref. AMM TASK 49-51-51-400-001).
(1) If the fault continues:
- disconnect connector P7 from the LOAD CONTROL VALVE (8050KM) P12 and check for a ground signal at pin P7/1 and P7/2. Do a repair if necessary (Ref. ASM 49-61/02).
- do a check and repair the wiring from the ECB (59KD) AB/F10, F11 to the LOAD CONTROL VALVE (8050KM) P12/1, 2 (Ref. ASM 49-61/02).
- do a check and repair the wiring from the ECB (59KD) AB/D7, D14 to the LOAD VALVE POSITION SWITCH P7/3, 4 (Ref. ASM 49-61/02).
(2) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).
R **ON A/C 001-003, 051-099, 401-499,
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-003, 051-099, 401-499, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page 289
Config-1 Aug 01/05 CES TASK 49-00-00-810-830
Surge Control-Valve Fault (GTCP 36-300)
1. Possible Causes_______________
- SURGE CONTROL VALVE P18
- wiring
- ECB (59KD)
- SURGE CONTROL VALVE (8058KM)
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 49-00-00-710-001 Self-Test of the ECB (59KD) (GTCP 36-300)
AMM 49-51-52-000-002 Removal of the Surge Control Valve (8058KM) (GTCP 36-300)
AMM 49-51-52-400-002 Installation of the Surge Control Valve (8058KM) (GTCP 36-300)