「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-003, 051-099, 401-499, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page A213
Config-1 Aug 01/05 CES
(1) If there is a ground signal and 115VAC:
- replace the OIL HEATER (8093KM) (Ref. AMM TASK 49-96-51-000-001) and (Ref. AMM TASK 49-96-51-400-001).
(a) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).
(2) If there is no ground signal:
- do a check and repair the wiring from the APU OIL HEATER (2KT) P6/2 to the ground (Ref. ASM 49-96/01).
(3) If there is no 115VAC power supply.
- replace the APU AUX CTL RELAY (32KD) (Ref. ASM 49-96/01).
(a) If the fault continues:
- do a check and repair the wiring from the APU OIL HEATER (2KT) P6/1 to the SERVICE BUS 2 (214XP-B) (Ref. ASM 49-96/01).
R **ON A/C 001-003, 051-099, 401-499,
TASK 49-00-00-810-841
APU AUTO SHUT DOWN - LOW OIL PRESSURE, Low Oil Quantity (GTCP 36-300)
1. Possible Causes
_______________
- the oil level is below the ADD mark
- TURBINE BEARING CAVITY VENT
- AUXILIARY POWER UNIT (4005KM)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 49-00-00-790-001 Check APU Compartment and Air Intake Duct for Oil Contamination (GTCP 36-300) AMM 49-11-11-000-001 Removal of the Auxiliary Power Unit (APU) - 4005KM
(GTCP 36-300) AMM 49-90-00-600-001 Check Oil Level and Replenish (GTCP 36-300) AMM 49-91-53-000-001 Removal of turbine bearing cavity vent and
lubrication tube packing (GTCP 36-300) AMM 49-91-53-400-001 Installation of turbine bearing cavity vent and lubrication tube packing (GTCP 36-300)
3. Fault Confirmation
__________________
A. Do a read out of the APU SHUTDOWNS report.
4. Fault Isolation
_______________ **ON A/C 001-003, 051-062,
A. If the APU SHUTDOWNS report gives the the maintenance message:
LOW OIL PRESSURE - LOW OIL LEVEL:
- do a check of the oil level.
(1) If the oil level is below the ADD mark:
- do the oil servicing (Ref. AMM TASK 49-90-00-600-001).
- calculate the APU oil consumption.
(a) If the APU oil consumption is more than 65 cm3 (3.96 in.3) per APU operating hour:
- examine the APU externally for oil leaks on the oil system components or oil lines (Ref. AMM TASK 49-00-00-790-001).
1 If you find external oil leaks:
_ - correct/replace as necessary.
2 If you do not find external oil leaks:
_
- examine the APU for internal oil leakage (Ref. AMM TASK 49-00-00-790-001).
- remove, clean and install the TURBINE BEARING CAVITY VENT (Ref. AMM TASK 49-91-53-000-001) and (Ref. AMM TASK 49-91-53-400-001).
a If the fault continues:
_
- replace the AUXILIARY POWER UNIT (4005KM) (Ref. AMM TASK 49-11-11-000-001) and (Ref. AMM TASK 49-11-11-000-001).
R **ON A/C 063-099, 401-499,
A. If the APU SHUTDOWNS report gives the the maintenance message:
LOW OIL PRESSURE - LOW OIL LEVEL:
with the LRU TROUBLE SHOOT DATA menu information
OIL LEVEL SHOWS LOW
Fault Code Number: 099
- do a check of the oil level.
(1) If the oil level is below the ADD mark:
- do the oil servicing (Ref. AMM TASK 49-90-00-600-001).
- calculate the APU oil consumption.
(a) If the APU oil consumption is more than 65 cm3 (3.96 in.3) per APU operating hour:
- examine the APU externally for oil leaks on the oil system components or oil lines (Ref. AMM TASK 49-00-00-790-001).
1 If you find external oil leaks:
_ - correct/replace as necessary.
2 If you do not find external oil leaks:
_
- examine the APU for internal oil leakage (Ref. AMM TASK 49-00-00-790-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-003, 051-099, 401-499, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page A216
Config-1 Aug 01/05 CES
- remove, clean and install the TURBINE BEARING CAVITY VENT (Ref. AMM TASK 49-91-53-000-001) and (Ref. AMM TASK 49-91-53-400-001). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 机载辅助动力 1(39)