(2) If one or two electrical parameter indications are replaced by amber
XX:
- replace the GCU-APU (1XS) (Ref. AMM TASK 24-23-34-000-001) and (Ref. AMM TASK 24-23-34-400-001).
(a) If the fault continues:
- replace the EGIU-2 (22XU2) (Ref. AMM TASK 24-22-33-000-001) and (Ref. AMM TASK 24-22-33-400-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-106, 108-149, 211-299, 301-399, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page A226
Config-2 Aug 01/05 CES
B. Do the test given in para. 3.
TASK 49-00-00-810-960
APU Bleed Control Valve indication replaced by amber XX (APS 3200)
1. Possible Causes
_______________
- BLEED CONTROL VALVE (8051KM) (LVDT Fault)
- ECB (59KD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
49-00-00-810-942 Bleed Control Valve Fault (APS 3200) AMM 31-32-00-860-001 Procedure to Get Access to the SYSTEM REPORT/TEST
Menu Page AMM 49-00-00-710-008 Operational Test of the APU (APS 3200) AMM 49-61-34-000-002 Removal of the Electronic Control Box (ECB) (59KD)
(APS 3200) AMM 49-61-34-400-002 Installation of the Electronic Control Box (ECB) (59KD) (APS 3200)
3. Fault Confirmation
__________________
A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-008).
(1) Do a check of the APU Bleed Control-Valve indication on the lower ECAM DU (APU Page).
(2) On the MCDU, get access to the APU menu page SYSTEM REPORT/TEST (Ref. AMM TASK 31-32-00-860-001).
(3) Select the LAST LEG REPORT page.
4. Fault Isolation
_______________
A. Maintenance Action
(1) If there is a CLASS 1 Fault Message BLEED CTL VLV (8051KM) and the Bleed Control Valve indication is replaced by amber XX:
- do the trouble shooting of the BLEED CONTROL VALVE (8051KM) (LVDT Fault) (Ref. TASK 49-00-00-810-942).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-106, 108-149, 211-299, 301-399, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page A228
Config-2 Aug 01/05 CES
(2) If there is no CLASS 1 Fault Message and the Bleed Control Valve indication is replaced by amber XX:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002).
B. Do the test given in para. 3.
TASK 49-00-00-810-961
APU Bleed Pressure indication replaced by amber XX (APS 3200)
1. Possible Causes
_______________
- BLEED FLOW XDCR (8039KM)
- ECB (59KD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
49-00-00-810-903 Bleed Flow-Transducer Fault (APS 3200) AMM 31-32-00-860-001 Procedure to Get Access to the SYSTEM REPORT/TEST
Menu Page AMM 34-10-00-860-002 ADIRS Start Procedure AMM 49-00-00-710-008 Operational Test of the APU (APS 3200) AMM 49-61-34-000-002 Removal of the Electronic Control Box (ECB) (59KD)
(APS 3200) AMM 49-61-34-400-002 Installation of the Electronic Control Box (ECB) (59KD) (APS 3200)
3. Fault Confirmation
__________________
A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-008). NOTE : Make sure that the ADIRUs are energized (Ref. AMM TASK 34-10-00-
____
860-002).
(1) Do a check of the APU Bleed Pressure indication on the lower ECAM DU (APU Page).
(2) On the MCDU, get access to the APU menu page SYSTEM REPORT/TEST (Ref. AMM TASK 31-32-00-860-001).
(3) Select the LAST LEG REPORT page.
4. Fault Isolation
_______________
A. Maintenance Action
(1) If there is a fault message BLEED FLOW XDCR (8039KM) and the Bleed Pressure indication is replaced by amber XX:
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-106, 108-149, 211-299, 301-399, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page A230
Config-2 Aug 01/05 CES
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 机载辅助动力 1(127)